background image

Perform Setup 

 

 

40 

 

The "IP Address" screen is displayed. 

  

 

  

Set network 
settings: 

Accept the network settings provided 

Reset to Factory: 

Reset to factory settings 

IP Address: 

Input field for the IP address 

Default Gateway: 

Input field for the gateway address 

Subnet Mask: 

Input field for data on the subnet mask 

IP Configuration 
Method 
Manual/DHCP: 

Assign an IP address manually or automatically 

  

Summary of Contents for WideTEK 36CL

Page 1: ...WideTEK 36 48CL Setup Instructions English 01 2018...

Page 2: ...y Information 8 Avoiding Property Damage and Malfunctions 10 Responsibility of the Owner 10 Staff Qualifications 10 Design Features of Warning Notices 11 Formatting of Information Regarding Property D...

Page 3: ...lance 30 Assign the IP Address 39 Modify User Settings 48 Set the Time and Date 55 Perform Test Suite 60 Touchscreen Test 63 Technical Specifications 67 Scanner Specification 67 Ambient Conditions 68...

Page 4: ...36 48CL The WideTEK 36 48CL scanners are hereinafter referred to as Scanner In these instructions the start button is called power button Keep Instructions with the Scanner These instructions are a p...

Page 5: ...ements as illustrated below Normal text BUTTONS OF THE SCREEN PAGE Menu names Action steps Enumeration of the first level Cross references Tips contain additional information such as special informati...

Page 6: ...fety EMI Certificates RoHS etc Copyright These instructions contains information that is subject to copyright These instructions may not be reproduced in any form printed filmed edited copied or distr...

Page 7: ...8 0 E Mail documentation imageaccess de Internet address www imageaccess de Technical Support Image Access technical support can be reached at the e mail address support imageaccess de Contact Data of...

Page 8: ...liability claims Ambient Conditions Ensure that the scanner is used exclusively under the following environmental conditions Ambient temperature during operation 5 C to 40 C Storage temperature 0 C to...

Page 9: ...ical Support starting at page 7 Avoid Burns Do not cover the existing openings in the scanner housing They serve to ventilate Covering the openings could cause overheating Do not place the scanner in...

Page 10: ...ickness of the material to be scanned does not exceed 2 5 mm Do not use any cleaning agents containing abrasive additives solvents or acids Use a damp microfiber cloth Operate the touchscreen only wit...

Page 11: ...ld lead to death or serious injuries CAUTION Notices with the word CAUTION warn about a situation that could lead to light or medium scale injuries The following symbols are used in the warnings Symbo...

Page 12: ...commercial sector Intended use also includes observing and following all instructions in these instructions especially the safety instructions Any other use is considered to be improper and will void...

Page 13: ...Description 13 Rear View No Name 1 USB connector 2 HDMI connector 3 Network connector 4 Recovery key connector 5 Main switch 6 19 V DC connector for external power supply...

Page 14: ...tton to leave the setup menu to the start screen 5 Button to drive the document forward in the scanner 6 Button to drive the document backward in the scanner rewind 7 Firmware version 8 IP address 9 S...

Page 15: ...Description 15 Rating Plate The rating plate is attached to the back of the scanner The following figure shows the WideTEK 36CL 600 rating plate...

Page 16: ...Description 16 The following figure shows the WideTEK 48CL 600 rating plate...

Page 17: ...ises can be the result Place the connecting cables so that nobody can trip over them To connect the power supply proceed as follows Make sure that the main switch of the scanner is switched off 0 posi...

Page 18: ...he back of the scanner Connect the second plug to the network socket of an existing network Positioning the Scanner on the Optional Floor Stand CAUTION The scanner weighs bewteen 53 lbs 24 kg and 63 l...

Page 19: ...ector socket located on the back of the scanner Connect the Optional Touchscreen CAUTION Incorrect laying of the connection cables can cause tripping Fractures contusions and bruises can be the result...

Page 20: ...e for Setup 20 Switch On the Scanner To switch on the scanner proceed as follows Press the MAIN SWITCH 1 on the back to the I position The scanner is in standby mode The power button is illuminated in...

Page 21: ...tart the scanner from standby mode proceed as follows Touch the green illuminated power button The power button lights up in blue The scanner performs a system test After a short wait the Start screen...

Page 22: ...ner to standby mode after performing the setup proceed as follows On the Start screen screen tap on SHUTDOWN 1 Confirm with YES The scanner shuts down This process can take up to 40 seconds The power...

Page 23: ...nner is in standby mode To switch off the scanner for longer periods proceed as follows Make sure that the scanner is in standby mode The power button is illuminated in green Press the MAIN SWITCH 1 i...

Page 24: ...Perform Setup 24 Perform Setup Change the Menu Language To change the menu language proceed as follows Tap the LANGUAGE 1 button...

Page 25: ...up 25 A window for selecting the language appears To display more languages slide the scroll bar 1 downward Tap the desired language The window for selecting the language is closed The Start screen is...

Page 26: ...Perform Setup 26 Activate the Setup Menu To activate the setup menu you have to log in on the scanner Proceed as follows Tap the GEAR SYMBOL 1...

Page 27: ...indow enter the login credentials To enter the credentials tap with your finger on the corresponding input field The screen keyboard is displayed Enter the word Poweruser in the fields Username 1 and...

Page 28: ...Perform Setup 28 To complete the log in press OK 1...

Page 29: ...ce submenu Testsuite Display the Test Suite submenu IP Address Display the IP Address submenu User Settings Display the User Settings submenu Time and Date Display the Time and Date submenu To select...

Page 30: ...Perform Setup 30 Perform White Balance On the Setup Menu screen tap on WHITE BALANCE 1...

Page 31: ...rt white balance Delete White Balance Data Delete existing white balance data The white balance is used to ensure the quality of the scan results The white balance will be carried out using a test tar...

Page 32: ...32 Before beginning the white balance procedure remove the transport guides To remove the transport guides proceed as follows Lift the transport guides 1 approximately 5 mm 1 Pull the transport guide...

Page 33: ...the test target is free from wrinkles discolorations cracks or other damage Store the test target for the white balance in a safe place protected from daylight To perform the white balance proceed as...

Page 34: ...Perform Setup 34 Tap on CALIBRATE 1...

Page 35: ...Perform Setup 35 Tap on NEXT STEP 1...

Page 36: ...is transported forward and returned The entire white balance sequence takes about 18 seconds Then the white balance result is displayed as shown on the example below On an error free white balance ca...

Page 37: ...Perform Setup 37 To perform the white balance again tap NEW VALUES 2 To return to the previous submenu tap BACK 1 To return to the Start screen tap EXIT 3...

Page 38: ...ation contact Image Access technical support see section Technical Support starting at page 7 To return to the previous submenu tap BACK 1 To return to the Start screen tap EXIT 3 After a successful w...

Page 39: ...Perform Setup 39 Assign the IP Address Manually Assign the IP Address To manually assign the IP address proceed as follows On the Setup Menu screen tap on IP Address 1...

Page 40: ...settings provided Reset to Factory Reset to factory settings IP Address Input field for the IP address Default Gateway Input field for the gateway address Subnet Mask Input field for data on the subn...

Page 41: ...Perform Setup 41 Tap the IP Address 1 field...

Page 42: ...Perform Setup 42 The IP Address window is displayed Enter the IP address 1...

Page 43: ...Perform Setup 43 To delete a digit move the cursor to the right behind the digit to be deleted and tap DEL 1...

Page 44: ...orm Setup 44 The arrow keys left 1 and right 2 next to the number 0 move the cursor within the chosen row To complete the entry press OK 3 Perform the settings for gateway and subnet mask in the same...

Page 45: ...Perform Setup 45 To save the network settings tap SET NETWORK SETTINGS 2 To return to the previous submenu tap BACK 1 To return to the Start screen tap EXIT 3...

Page 46: ...Perform Setup 46 Automatically Assign the IP Address To automatically assign the IP address proceed as follows On the setup menu screen press the button IP ADDRESS 1...

Page 47: ...Perform Setup 47 In the selection menu IP Configuration Method select the DHCP 3 entry To return to the previous submenu tap BACK 1 To return to the Start screen tap EXIT 2...

Page 48: ...Perform Setup 48 Modify User Settings On the Setup Menu screen tap on USER SETTINGS 1...

Page 49: ...gs will be established again Language Select language Display standby after Define the period of inactivity until an optional external monitor and the touchscreen switch to the standby mode Screen Sav...

Page 50: ...t the language proceed as follows Tap the on the selection arrow of the selection menu Language to display the list of languages Tap the desired language 2 To return to the previous submenu tap BACK 1...

Page 51: ...proceed as follows Tap the selection arrow of the selection menu Tap on the desired entry 2 Perform the settings for the screen saver and the device standby in the same way To return to the previous...

Page 52: ...Perform Setup 52 Configuring the GUI Selection Tap the User Settings screen on CONFIGURE GUI SELECTION 1...

Page 53: ...isplays the EasyScan and ScanWizard applications which are available as a standard selection If after system start you want to display only one of the applications proceed as follows Under Displays 1...

Page 54: ...b mode is defined disable the checkbox Single mode enabled To start the application in standalone mode check the checkbox Single mode enabled 2 To return to the previous submenu tap BACK 1 To return t...

Page 55: ...Perform Setup 55 Set the Time and Date On the Setup Menu screen tap on TIME and DATE 1...

Page 56: ...56 The screen Time and Date appears Enter new time Enter hours and minutes with the arrow keys Enter new date Open a calendar to set the date Store time and date Accept the set values Time Zone Selec...

Page 57: ...ap the Enter new time field To set the time later tap the up arrow 2 To set the time earlier tap the down arrow 2 To save the modified time click STORE TIME AND DATE 3 To return to the previous submen...

Page 58: ...elect the appropriate date in the calendar 3 To set the month and year tap the arrow keys 2 4 at the top of the calendar To set the day tap the corresponding day in the calendar To save the date click...

Page 59: ...he selection arrow 4 A selection list with available time zones is displayed Select the appropriate time zone To save the time zone click STORE TIME AND DATE 2 To return to the previous submenu tap BA...

Page 60: ...Perform Setup 60 Perform Test Suite On the Setup Menu screen tap on TESTSUITE 1...

Page 61: ...1 The Testsuite screen is displayed Information about the mainboard Display the current values for Temperature of PCB and CPU cores fan speed PCB voltages Information for testing electromagnetic compa...

Page 62: ...EMV test The EMV test may only be performed by certified service technicians To perform the electromagnetic compatibility test select on 3 in the EMV Test selection menu To return to the previous subm...

Page 63: ...Perform Setup 63 Touchscreen Test To check the functionality of the touchscreen when touched proceed as follows On the Setup Menu screen tap on TOUCHSCREEN TEST 1...

Page 64: ...een is displayed To perform the Touchscreen Test tap with your finger on the corresponding screen 3 The crosshairs must occupy the same position as the finger To end the Touchscreen Test tap STOP TOUC...

Page 65: ...Perform Setup 65 The Event Test screen is displayed The X button 2 cancels the test and returns to the start screen Touchscreen Test Hold the upper left blinking green rectangle 1 with your finger...

Page 66: ...ou arrive at the top right move down one line and move then to the left again Continue with this procedure until you have reached the lower right edge of the screen This test can be aborted at any tim...

Page 67: ...optionally 9600 9600 dpi interpolated Pixel dimension 42 x 42 m Sensor type Three dual light CIS modules Color Depth 48 bit color internal resolution 16 bit grayscale internal resolution Scan modes 24...

Page 68: ...bit color internal resolution 16 bit grayscale internal resolution Scan modes 24 bit color 8 bit color indexed 8 bit grayscale bitonal enhanced halftone File formats Multipage PDF PDF A and TIFF JPEG...

Page 69: ...andard CEC Level VI Scanner Voltage 19 Vdc Current 3 A Power Consumption Sleep 0 5 W Standby approx 5 W Ready to scan 25 W Scanning 45 W Document Specification Document length up to 500 m 20 000 inch...

Page 70: ...x 10 2 inches Scanner weight ready to ship 32 kg 70 5 lbs Floor stand weight ready to ship 21 kg 46 lbs Dimensions and Weight WideTEK 48CL 600 Scanner outer dimensions H W x D 170 x 1418 x 358 mm 6 7...

Page 71: ......

Page 72: ......

Reviews: