background image

 

Technical Information

 

 

Ilumipod Inground Tri-3 IP Optic 25 WW User Manual Rev. 3 

 

13 

5. Technical Information  

 
 
 
 
 
 
 
 
 
 
 

Always dry the 
external optics 
and glass 
surfaces carefully 

after cleaning them. 
 
 
 
 

If you still 
experience 
technical 
problems after 

trying the solutions in the 
Troubleshooting Table, 
contact 

ILUMINARC

®

 

Technical Support

 

Product Maintenance 

To maintain optimum performance and minimize wear, clean the products frequently. Usage 
and environment are contributing factors in determining the cleaning frequency. As a general 
guideline,  products  should be cleaned at least twice a month. Dust build-up reduces light 
output, performance, and can cause overheating. This can lead to reduced light source life. 
For  products containing external optical lenses, clean them periodically to optimize light 
output. The cleaning frequency depends on the environment in which the product  operates. 
Damp, smoky, or particularly dirty surrounding can cause greater accumulation of dirt on the 
product’s optics, requiring more frequent cleaning. 
To clean a product: 

 

Disconnect the product from power. 

 

Wait until the product is at room temperature. 

 

Use a vacuum (or dry compressed air) and a soft brush to remove dust collected on the 
external surfaces. 

 

Clean all external glass optics and glass surfaces with a mild solution of glass cleaner or 
isopropyl alcohol, and a soft, lint-free cotton cloth or lens-cleaning tissue. 

 

Apply the solution directly to the cloth or tissue and wipe any dirt and grime to the outside 
edge of the lens. Gently polish the external glass surfaces until they are free of haze and 
lint. 

Product Repairs 

ILUMINARC® strongly advises you against attempting any repairs to this product unless you 
are an authorized ILUMINARC® technician.  
ILUMINARC® presents the information contained in the 

Troubleshooting Guide

 as potential 

solutions only. In most cases, opening the product’s housing will invalidate its warranty. 
 
 

 

 
 
 
 
 

 

Summary of Contents for Ilumipod Inground Tri-3 IP Optic 25 RGB

Page 1: ...Ilumipod Inground Tri 3 IP Optic 25 WW User Manual...

Page 2: ...on modification or printing of this manual or its content for any other purpose without its written consent Document Printing For better results print this document in color on letter size paper 8 5 x...

Page 3: ...Overview 4 Dimensions 5 3 Installation 6 Installation Notes 6 Installation Sleeve Orientation 6 Installation Sleeve Setup 6 AC Power 7 Power Consumption 7 AC Plug 7 Power Wiring 7 DMX Linking 8 DMX Mo...

Page 4: ...er Manual Rev 3 5 Technical Information 13 Product Maintenance 13 Product Repairs 13 Troubleshooting Guide 14 Photometrics 15 LED Disclaimer 16 LED Life 16 LED Binning 16 Color Rendering Index CRI 16...

Page 5: ...aims The carrier is responsible for any damage incurred during shipping Therefore if the received merchandise appears to have been damaged during shipping the customer must submit the damage report an...

Page 6: ...d direct eye exposure to the light source while the product is on Always disconnect this product from its power source before servicing Always connect this product to a grounded circuit to avoid the r...

Page 7: ...l unit drive over rated glass lens cover and tri emitter LEDs Features 1 channel warm white LED in ground wash light Operating mode 1 channel Dimmer Five distinct dimming curves IP67 stainless steel g...

Page 8: ...Product Description 4 Ilumipod Inground Tri 3 IP Optic 25 WW User Manual Rev 3 Overview Tri emitter LEDs Installation Sleeve 316 Stainless Steel Gland Nuts...

Page 9: ...Product Description Ilumipod Inground Tri 3 IP Optic 25 WW User Manual Rev 3 5 Dimensions 0 2 in 4 mm 4 2 in 107 mm 5 6 in 141 mm 6 0 in 153 mm 7 in 178 mm...

Page 10: ...ntation You will have to run the AC power and signal cables from the base of the fixture into the installation sleeve Position the installation sleeve so that the signal cable exits the sleeve using o...

Page 11: ...sticker Power Consumption To determine the power requirements for the Ilumipod Inground Tri 3 IP Optic 25 WW refer to the label affixed to the side of the product Alternatively you may refer to the T...

Page 12: ...l each individually with a single DMX controller If you are not familiar with the DMX standard or if you need information about the DMX cables needed to link the Ilumipod Inground Tri 3 IP Optic 25 WW...

Page 13: ...provide information on how to connect these products to the corresponding controllers The instructions to operate these products with each of the above controllers are in the Operation chapter of this...

Page 14: ...ft Otherwise you might need to use an optically isolated signal amplifier Ilumicode Addresser The Ilumipod Inground Tri 3 IP Optic 25 WW uses the Ilumicode addresser Ilumicode for configuration purpo...

Page 15: ...hrough the menu list and decreases the numeric value when in a function POWER Turns the unit on The unit will turn off automatically after 30 seconds of inactivity Control Options You can set the Ilum...

Page 16: ...on OFF Dimmer curve is linear with fader DIM1 Non linear fastest DIM2 Non linear fast DIM3 Non linear slow DIM4 Non linear slowest Reset to Factory Settings 1 Go to SETTINGS RESET 2 Select YES or NO M...

Page 17: ...which the product operates Damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the product s optics requiring more frequent cleaning To clean a product Disconnect th...

Page 18: ...ressing Damaged DMX cables Check DMX cables Wrong polarity on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faulty DMX interface Return for s...

Page 19: ...dela 2 885 7 at Horizontal 0 Vertical 1 Input Wattage 9 8 Luminous Opening Point Test 20120523 Test Date 2012 05 23 Test Lab ILUMINARC R D Photometry Type B CIE Class Direct Flood Summary Efficiency L...

Page 20: ...ons and inconsistencies related to CRI Results may vary depending on the environmental factors involved For this reason the U S Department of Energy DOE states that CRI should be considered as one poi...

Page 21: ...of the cause for the return The user must clearly label the package with an RMA ILUMINARC will refuse any product returned without an RMA DO NOT write the RMA directly on the box Instead write it on a...

Page 22: ...V 60 Hz 230 V 50 Hz Consumption 10 W 11 W Operating current 0 2 A 0 1A Power I O Input Output Connectors Open Wire N A Cord plug N A N A Light Source Type Power Lifespan LED 2 3 W 50 000 hours Color C...

Page 23: ...ILUMINARC 5200 NW 108th Avenue Sunrise FL 33351 U S A Voice 954 923 3680 www iluminarc com Ilumipod Inground Tri 3 IP Optic 25 WW User Manual Rev 3 December 2013...

Reviews: