background image

 

Edition Notes

 

Ilumipod Inground Tri-3 IP Optic 25 WW User Manual Rev. 3 

Edition Notes 

The  Ilumipod Inground Tri-3 IP Optic 25 WW  User Manual Rev. 3  covers the description, 
safety precautions, installation, programming, operation, and maintenance of the Ilumipod 
Inground Tri-3 IP Optic 25 WW. ILUMINARC® released this edition of the Ilumipod 
Inground Tri-3 IP Optic 25 WW User Manual Rev. 3 in December 2013. 

Trademarks 

The ILUMINARC® logo, the ILUMINARC® name and all other trademarks in this document 
related to services or products by ILUMINARC® are trademarks owned or licensed by 
ILUMINARC®, its affiliates or subsidiaries. Any other product names, logos, brands, 
company names, trademarks featured or referred to within this document are the property of 
their respective trademark holders. 

Copyright Notice 

The entire content of this document, except where applicable and unless otherwise noted, is 
solely owned by ILUMINARC®, a wholly owned trademark of CHAUVET & Sons, Inc. 
(d/b/a CHAUVET® or Chauvet). 

© Copyright 2013 ILUMINARC®. 

All rights reserved. 
Electronically published by ILUMINARC® in the United States of America. 

Manual Usage 

ILUMINARC® authorizes its  customers to download and print this manual for professional 
information purposes only. ILUMINARC®  expressly prohibits the usage, copy, storage, 
distribution, modification, or printing of this manual or its content for any other purpose 
without its written consent.  

Document Printing 

For better results, print this document in color, on letter size paper (8.5 x 11 in), double-sided. 
If using A4 paper (210 x 297 mm), configure your printer to scale the content of this 
document to A4 paper. 

Intended Audience 

Any person in charge of installing, operating, and/or maintaining the Ilumipod Inground Tri-3 
IP Optic 25 WW should read all of both the guide that shipped with it and this User Manual 
before installing, operating, or maintaining this product. 

Disclaimer 

ILUMINARC® believes that the information contained in this manual is accurate in all 
respects. However, ILUMINARC® assumes no responsibility for any error or omissions in 
this document. ILUMINARC® reserves the right to revise this document and to make changes 
from time to time in the content hereof without obligation of ILUMINARC® to notify any 
person or company of such revision or changes. This does not constitute in any way a 
commitment by ILUMINARC® to make such changes. ILUMINARC® may issue a revision 
of this manual or a new edition of it to incorporate such changes. 

Document Revision 

The  Ilumipod Inground Tri-3 IP Optic 25 WW  User Manual Rev. 3  supersedes all previous 
versions of this manual. Please discard any older versions of this manual you may have, 
whether in printed or electronic format, and replace them with this version. 

Author 

Date 

Editor 

Date 

D. Couppe 

11/27/13 

A. Leon 

12/04/13 

 

Summary of Contents for Ilumipod Inground Tri-3 IP Optic 25 RGB

Page 1: ...Ilumipod Inground Tri 3 IP Optic 25 WW User Manual...

Page 2: ...on modification or printing of this manual or its content for any other purpose without its written consent Document Printing For better results print this document in color on letter size paper 8 5 x...

Page 3: ...Overview 4 Dimensions 5 3 Installation 6 Installation Notes 6 Installation Sleeve Orientation 6 Installation Sleeve Setup 6 AC Power 7 Power Consumption 7 AC Plug 7 Power Wiring 7 DMX Linking 8 DMX Mo...

Page 4: ...er Manual Rev 3 5 Technical Information 13 Product Maintenance 13 Product Repairs 13 Troubleshooting Guide 14 Photometrics 15 LED Disclaimer 16 LED Life 16 LED Binning 16 Color Rendering Index CRI 16...

Page 5: ...aims The carrier is responsible for any damage incurred during shipping Therefore if the received merchandise appears to have been damaged during shipping the customer must submit the damage report an...

Page 6: ...d direct eye exposure to the light source while the product is on Always disconnect this product from its power source before servicing Always connect this product to a grounded circuit to avoid the r...

Page 7: ...l unit drive over rated glass lens cover and tri emitter LEDs Features 1 channel warm white LED in ground wash light Operating mode 1 channel Dimmer Five distinct dimming curves IP67 stainless steel g...

Page 8: ...Product Description 4 Ilumipod Inground Tri 3 IP Optic 25 WW User Manual Rev 3 Overview Tri emitter LEDs Installation Sleeve 316 Stainless Steel Gland Nuts...

Page 9: ...Product Description Ilumipod Inground Tri 3 IP Optic 25 WW User Manual Rev 3 5 Dimensions 0 2 in 4 mm 4 2 in 107 mm 5 6 in 141 mm 6 0 in 153 mm 7 in 178 mm...

Page 10: ...ntation You will have to run the AC power and signal cables from the base of the fixture into the installation sleeve Position the installation sleeve so that the signal cable exits the sleeve using o...

Page 11: ...sticker Power Consumption To determine the power requirements for the Ilumipod Inground Tri 3 IP Optic 25 WW refer to the label affixed to the side of the product Alternatively you may refer to the T...

Page 12: ...l each individually with a single DMX controller If you are not familiar with the DMX standard or if you need information about the DMX cables needed to link the Ilumipod Inground Tri 3 IP Optic 25 WW...

Page 13: ...provide information on how to connect these products to the corresponding controllers The instructions to operate these products with each of the above controllers are in the Operation chapter of this...

Page 14: ...ft Otherwise you might need to use an optically isolated signal amplifier Ilumicode Addresser The Ilumipod Inground Tri 3 IP Optic 25 WW uses the Ilumicode addresser Ilumicode for configuration purpo...

Page 15: ...hrough the menu list and decreases the numeric value when in a function POWER Turns the unit on The unit will turn off automatically after 30 seconds of inactivity Control Options You can set the Ilum...

Page 16: ...on OFF Dimmer curve is linear with fader DIM1 Non linear fastest DIM2 Non linear fast DIM3 Non linear slow DIM4 Non linear slowest Reset to Factory Settings 1 Go to SETTINGS RESET 2 Select YES or NO M...

Page 17: ...which the product operates Damp smoky or particularly dirty surrounding can cause greater accumulation of dirt on the product s optics requiring more frequent cleaning To clean a product Disconnect th...

Page 18: ...ressing Damaged DMX cables Check DMX cables Wrong polarity on the controller Check polarity switch settings on the controller Loose DMX cables Check cable connections Faulty DMX interface Return for s...

Page 19: ...dela 2 885 7 at Horizontal 0 Vertical 1 Input Wattage 9 8 Luminous Opening Point Test 20120523 Test Date 2012 05 23 Test Lab ILUMINARC R D Photometry Type B CIE Class Direct Flood Summary Efficiency L...

Page 20: ...ons and inconsistencies related to CRI Results may vary depending on the environmental factors involved For this reason the U S Department of Energy DOE states that CRI should be considered as one poi...

Page 21: ...of the cause for the return The user must clearly label the package with an RMA ILUMINARC will refuse any product returned without an RMA DO NOT write the RMA directly on the box Instead write it on a...

Page 22: ...V 60 Hz 230 V 50 Hz Consumption 10 W 11 W Operating current 0 2 A 0 1A Power I O Input Output Connectors Open Wire N A Cord plug N A N A Light Source Type Power Lifespan LED 2 3 W 50 000 hours Color C...

Page 23: ...ILUMINARC 5200 NW 108th Avenue Sunrise FL 33351 U S A Voice 954 923 3680 www iluminarc com Ilumipod Inground Tri 3 IP Optic 25 WW User Manual Rev 3 December 2013...

Reviews: