FUELING
MOTOR FUEL:
mix the petrol and oil at 40:1 only
Mixing table for fuel mixture
Petrol
2-stroke oil / 40:1
1 litre
25 ml
5 litres
125 ml
1. Use fresh unleaded petrol. You must use 100%
synthetic oil specifically made for heavily stressed
two stroke engines.
2. Mix the petrol and oil in an approved container.
Never mix fuel directly in the line trimmer fuel tank.
3. Place the brush cutter upright on the ground or on
a sturdy bench and wipe any debris from around
the fuel cap.
4. Unscrew the fuel tank cap and pour the mixture into
the tank with the aid of a funnel.
5. Be careful not to spill any mixture. If this happens,
wipe the spill with a clean rag.
6. Start the engine at least three metres away from
the area where the fuel tank has been filled up in
order to avoid any risk of fire.
Danger of fire and burn injuries
• Always use extreme care when handling fuel! Fuel
is highly flammable.
• Never attempt to fuel the line trimmer if the fuel sys-
tem components are damaged or are leaking.
• Never attempt the refuel the engine while it is run-
ning or still warm, allow it to cool before fueling.
• Never smoke or light any fires near the line trimmer
or fuels.
• Always transport and store fuels in an approved
container.
• Never operate the line trimmer without a properly
functioning muffler and spark arrestor installed.
• Never operate the line trimmer unless it is properly
assembled and in good working condition.
• Do not use petrol which contains ethanol or metha-
nol as it may damage the fuel lines and other engine
parts.
• Mix only enough fuel for your immediate needs. If
GB-9
fuel must be stored longer than 30 days, it should
first be treated with a stabilizer or similar product.
OPERATION
Plug the Blower/Vac into the mains supply.
Note:
To reduce the risk of injury, safety
switches are installed for the nozzle and dust
bag. The Blower/Vac can not be turned on
unless the nozzle and dust bag are attached.
Operating
1. Set the mode selection lever (7) to the right posi-
tion Ensure the level have clicked to place and is
rotated to the furthest point.
7
2. Push the switch (6) to power on marked “I”.
6
3. Place the choke lever in position A .
A
Summary of Contents for BLS 1000
Page 2: ......
Page 74: ......
Page 93: ......
Page 94: ...RU 1 2 3 4 5 6 7 7 7 7 8 9 9 9 10 10 10 10 10 11 12 12 12 12 12 12 12 12 13 13 13 14 14...
Page 95: ...RU 2 2 BLS 1000...
Page 96: ...RU 3 GPSG EC 80 dB A 15 50 9 30...
Page 97: ...RU 4...
Page 98: ...RU 5 15 50 A B C A B C...
Page 99: ...RU 6 1 2 3 4 14 5 6 7 9 8 11 10 12 13 15 RU 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15...
Page 100: ...RU 7 1 3 A A A 2 B 2 C B C 3 D D 4 1 2...
Page 101: ...RU 8 1 2 3 4 5 6...
Page 102: ...40 1 2 40 1 1 25 ml 5 125 ml 1 100 2 3 4 5 6 RU 9 30 1 7 7 2 6 I 6...
Page 104: ...RU 11 A 7 A A 1 2 7 B 7...
Page 105: ...RU 12 3 4 A 1 2 3 a b c d e f 1 60 2 3 1 30 ml 4...
Page 133: ......
Page 134: ......
Page 135: ......