iKoustic Limited,
Units 4 & 5, Erivan Park, Sandbeck Way,
Wetherby, West Yorkshire, LS22 7DN
Creating Quieter Spaces Together
www.iKoustic.com
01937 588226
[email protected]
8
MuteClip
®
Installation Guide
Ceiling
Direct to Concrete Ceiling
Instructions
• Measure up the ceiling you will be treating and mark out the locations for the clips
(See configurations or contact
iKoustic for appropriate dimensions).
+
The perimeter MuteClips should be no further than 100mm from the adjacent walls.
• Securely anchor bolt the MuteClips directly into the concrete ceiling at the appropriate centres
(See configurations
or contact iKoustic for appropriate dimensions).
• Attach MuteClip Channels into MuteClips.
+
MuteClip Channels should overlap by 200mm, fix 4 self-tapping screws into the shoulders of the channels to
give a secure join.
• MuteClip Channels should not overlap on a MuteClip.
• Insert Acoustic Mineral Wool behind the MuteClip Channels.
MuteClip to Concrete Substrate
1st Plasterboard to Channel
2nd Plasterboard to Channel
MuteClip Channel Overlap
Anchor Bolt
32mm Fine Thread Dry Wall Screw
50mm Fine Thread Dry Wall Screw
20mm Steel Self-Tapping Screw
-
-
-
-
Fixings
Suitability of fixings to be confirmed by installer.