MuteClip Channels must not overlap on a MuteClip.
•
Fix your first layer of Acoustic Plasterboard to the MuteClip Channels.
+
Acoustic Plasterboard must not be in direct contact with any adjacent surfaces. There must be a 2-5mm gap
around the perimeter of the room.
• Seal the perimeter and any other gaps with Acoustic Sealant.
• Adhere Tecsound to the Acoustic Plasterboard using Tecsound’s self-adhesive backing.
+
It may be easier to cut Tecsound into manageable sized pieces for ease of installation.
•
Fix your second layer of Acoustic Plasterboard and stagger the joins from the first layer, making sure that the
screws go into the MuteClip Channels.
+
Again, leave a 2-5mm gap around the perimeter of the room.
• Seal the perimeter and any other gaps with Acoustic Sealant.
•
Scrim tape all joins and finish with a skim plaster.
Configurations
Standard Diamond