Installation Guide
Wall
To Stud Wall
Instructions
• Install a Stud wall 5mm off the original wall.
+
600mm centres for the stud vertical structs with sufficient noggins to strengthen the structure.
• Insert Acoustic Mineral Wool between the stud frame.
+
Acoustic Mineral Wool can be friction-held between the joists/battens, if required use thin wiring to keep it
suspended.
• Measure up and mark out the appropriate locations for the MuteClips
(See configurations or contact iKoustic for
appropriate dimensions).
+
The perimeter MuteClips must be no further than 100mm from the adjacent surfaces.
• MuteClips to be spaced a maximum of 600mm apart vertically.
MuteClip to Stud Frame
1st Plasterboard to Channel
2nd Plasterboard to Channel
MuteClip Channel Overlap
5mm x 60mm Wood Screw
32mm Fine Thread Dry Wall Screw
50mm Fine Thread Dry Wall Screw
20mm Steel Self-Tapping Screw
Fixings
-
-
-
-
Suitability of fixings to be confirmed by installer.