use TTL cord with a non-TTL Substrobe; you will damage the camera.
•
D
DO
O N
NO
OTT
leave the sync cord connected to the camera or strobe for prolonged
periods as electrolysis can make removal impossible.
•
D
DO
O N
NO
OTT
disconnect the sync cord from the camera or strobe underwater or
when wet. Connections are NOT waterproof when not connected.
T
Thhee ccoonnnneeccttoorr tthhrreeaaddss aarree vveerryy ffiinnee;; DDO
O N
NO
OTT ccrroossss tthhrreeaadd..
I
Iff iitt iiss ddiiffffiiccuulltt ttoo ttuurrnn,, yyoouu aarree ccrroossss tthhrreeaaddiinngg..
L
LU
UBBRRIICCAAN
NTT
• Use only Ikelite brand silicone lubricant with Ikelite brand o-rings as other
brand lubricants can cause the Ikelite o-rings to swell in size.
•
D
DO
O N
NO
OTT
use spray lubricant as it may cause cracking of the plastic.Ikelite silicone
lubricant is provided for the sync cord o-ring. Use only enough lubricant to lightly
cover the o-ring; wipe off any excess with a clean cloth.
• Lubricant only reduces friction; it is NOT a sealant.
Retaining
Ring
Stem O-ring
Ikelite
Index Groove
Stem O-ring
Retaining
Ring
Nikonos
1177
S
STTRRO
OBBEE CCO
ON
NN
NEECCTTIIO
ON
N
The female Ikelite bulkhead connector on the strobe permits different Ikelite sync
cords or the Ikelite DS Sensor or EV-Controller to be connected. The sync cord or sensor
relays the trigger signal to the Substrobe.
The removable waterproof cap seals the bulkhead connector when neither the cord
nor the sensor is connected. The strobe bulkhead connector must be sealed to remain
waterproof.
•• D
DO
O N
NO
OTT
use TTL cord with a non-TTL Substrobe; you will damage the camera.
•
D
DO
O N
NO
OTT
leave the sync cord or sensor connected to the strobe for
prolonged
periods as electrolysis can make removal impossible.
•
D
DO
O N
NO
OTT
disconnect the sync cord or sensor from the strobe while underwater
or when wet. Connections are NOT waterproof when not connected.
CCO
ON
NN
NEECCTTIIO
ON
N TTO
O SSTTRRO
OBBEE________________________________________________________________________________________
Connect either the sync cord or sensor to the Substrobe in the same manner.
T
Thhee ccoonnnneeccttoorr tthhrreeaaddss aarree vveerryy ffiinnee;; DDO
O N
NO
OTT ccrroossss tthhrreeaadd..
I
Iff iitt iiss ddiiffffiiccuulltt ttoo ttuurrnn,, yyoouu aarree ccrroossss tthhrreeaaddiinngg..
1. Turn the Substrobe OFF and make sure all components are dry. Clean and lightly
lubricate the stem o-ring and the strobe bulkhead connector threads. Check o-ring for
nicks or cuts. Never use spray lubricant.
2. Note the positioning of the receptacles and pins. Properly align the end of the
cord and insert into the strobe bulkhead connector. When using the #4103.51 cord,
which connects an Ikelite housing to an Ikelite Substrobe, both cord ends are identical;
either end can be connected to the strobe.
3. Hand-tighten the knurled retaining ring on the cord. Push the connector body
further into the bulkhead connector and continue to tighten the knurled ring.
L
LU
UBBRRIICCAAN
NTT
• Use only Ikelite brand silicone lubricant with Ikelite brand o-rings as other
brand
lubricants can cause the Ikelite o-rings to swell in size.
•
D
DO
O N
NO
OTT
use spray lubricant as it may cause cracking of the plastic.
• Ikelite silicone lubricant is provided for the cord o-ring. Use only enough
lubricant
to lightly cover the o-ring; wipe off any excess with a clean cloth.
•
Lubricant only reduces friction; it is NOT a sealant.