background image

2244

Wing Nut

Ball Clamp

Strobe
Mount

Release Button

Stem

Release Handle

Ikelite

Substrobe

Ball Socket

Ball
Clamp

Wing
Nut

Ball
Socket

2233

M

MO

OU

UN

NTTIIN

NGG  TTH

HEE  SSTTRRO

OBBEE

IIKKEELLIITTEE  AARRM

M  SSYYSSTTEEM

MSS ______________________________________________________________________________________________

Ikelite offers several arm choices compatible with the DS125. The arm is NOT

supplied with the strobe unless purchased as part of a complete package.

Ikelite arm systems are designed for underwater use and may not hold the

adjustment ABOVE WATER due to the weight of some large strobes. Be careful when

transporting the system since some camera trays may not be able to support the weight

of the strobe above water.

The strobe will feature either a paddle-type or ball-type mount on the underneath

side. Please read the following arm sections for additional information.

S

STTRRO

OBBEE  AARRM

M    #

#44007755..11

The versatile Ikelite Strobe Arm offers multiple aiming positions. A second arm

section with second joint can be added if desired, #4076.2 

M

MO

OU

UN

NTT  SSTTRRO

OBBEE  TTO

O  AARRM

M ________________________________________________________________________________________

The paddle-type strobe mount may be featured on the DS125 and secures to most

Ikelite arm systems. The paddle-type mount is required for compatibility with the arm

4075.1 and it allows the strobe to tilt forward and backward. The rubber gasket on the

strobe mount creates friction against the arm and should NOT be lubricated.

Remove wing nut from strobe mount. Place the top of the arm against the rubber

gasket on the strobe mount. Replace the wing nut and tighten to secure. This

adjustment allows the strobe to pivot at the top of the arm. Rubber gasket creates

friction to hold  the adjustment underwater and should NOT be lubricated.

M

MO

OU

UN

NTT  AARRM

M  TTO

O  H

HO

OU

USSIIN

NGG ____________________________________________________________________________________

The stem protruding at the base of the arm snaps into the release handle on the

Ikelite housing. The stem also provides a convenient location for securing the optional

DS Slave Sensor or EV-Controller.

Insert the stem into the release handle. Depress the handle's release button and slide

the stem fully into the receptor. Release the button and it should spring back to the

original position locking the arm in place.

AAIIM

M  TTH

HEE  SSTTRRO

OBBEE________________________________________________________________________________________________________

Loosen the large four-lobed knob on the knuckle and insert the arm tube. The arm

can be rotated 360°, pivoted sideways, and also rotated forward and backward before

retightening the knob.

Summary of Contents for DS-125

Page 1: ...nos 1 5mm or SLR 20mm with diffuser G Gu ui id de e N Nu um mb be er r I IS SO O 1 1 0 00 0 f fe ee et t 64 surface 32 underwater G Gu ui id de e N Nu um mb be er r I IS SO O 1 1 0 00 0 m me et te er rs s 20 surface 1 0 underwater F Fi ir ri in ng g M Mo od de es s TTL Auto Manual 1 2 M 1 4 M 1 8 M Slave featuring auto exposure using optional DS Sensor 41 00 5 Slave featuring 1 0 manual power sett...

Page 2: ...sual ready light indicates when strobe has recycled Female Ikelite bulkhead connector accepts different camera sync cords the Ikelite DS Sensor 41 00 5 or EV Controller 41 00 6 Exposure guide label references recommended exposure settings Separate diffuser provides softer lighting and wider coverage angle Strobe mount accommodates most Ikelite arm systems B BE EC CO OM MI IN NG G F FA AM MI IL LI ...

Page 3: ...e has provided proper exposure This green confidence light illuminates only in the TTL exposure mode F FI IR RI IN NG G M MO OD DE E S SW WI IT TC CH H_ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Multiple firing modes are featured TTL Auto and four manual power settings Full 1 2 1 4 and 1 8 T TT TL L A...

Page 4: ...the strobe or the NiMH pack We suggest storage of your strobe with the locking lever OPEN to allow any hydrogen air mixture to escape O O R RI IN NG G _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ The o ring is located on the inside rim of the NiMH pack Keep the...

Page 5: ...ch is in the TEST position It is normal for the modeling light to flicker every few seconds as the strobe capacitors recharge The momentary power drain on the batteries causes the flickering as the strobe recycles B BU UL LB B_ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _...

Page 6: ...rds the Smart Charger will automatically switch to provide a trickle maintenance charge Only the Smart Charger is capable of providing a trickle maintenance charge permitting the NiMH pack to be continuously charged for extended periods C CO ON NT TI IN NU UO OU US S i il ll lu um mi in na at te ed d l li ig gh ht t Indicates that the NiMH module is being quick charged S SL LO OW W B BL LI IN NK K...

Page 7: ...uence too quick for the Ikelite DS Sensor to identify proper auto exposure and the Ikelite EV Controller 41 00 6 would then be recommended instead For maximum control using manual exposure choose the optional Ikelite EV Controller 41 00 6 which connects to the DS1 25 strobe and provides 1 0 manual power settings in half stop increments The EV Controller can be triggered using the built in slave se...

Page 8: ...e Substrobe has recycled and is ready to fire If the Ikelite housing does not feature TTL compatible circuitry then the ready light in the camera viewfinder would not be triggered when the strobe has recycled T Tr ri ig gg ge er re ed d v vi ia a S Sl la av ve e S Se en ns so or r When using the DS1 25 strobe with the optional DS Sensor or EV Controller without optional sync cord the strobe is not...

Page 9: ...e camera D DO O N NO OT T leave the sync cord or sensor connected to the strobe for prolonged periods as electrolysis can make removal impossible D DO O N NO OT T disconnect the sync cord or sensor from the strobe while underwater or when wet Connections are NOT waterproof when not connected C CO ON NN NE EC CT TI IO ON N T TO O S ST TR RO OB BE E_ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _...

Page 10: ... __ __ __ __ __ __ __ _ 4 41 10 03 3 5 51 1Single strobe cord 4 41 10 03 3 5 52 2 Dual strobe cord These cords connect Ikelite Substrobes to Ikelite camera housings Use TTL Auto or manual exposure modes C Co on nn ne ec ct t I Ik ke el li it te e H Ho ou us si in ng g 1 Make sure all components are dry Clean and lightly lubricate the stem o ring and the housing connector threads Check the o ring f...

Page 11: ...fuser so the tabs on the front lock the diffuser in place 3 To remove the diffuser rotate the diffuser so the cut outs align with the tabs on the front Grasp the protruding ears on the diffuser to remove 4 A lanyard can be attached to the diffuser by threading it thru the two circular openings on the diffuser U US SE E O OF F T TH HE E D DI IF FF FU US SE ER R_ __ __ __ __ __ __ __ __ __ __ __ __ ...

Page 12: ...atured on the DS1 25 and secures to most Ikelite arm systems The paddle type mount is required for compatibility with the arm 4075 1and it allows the strobe to tilt forward and backward The rubber gasket on the strobe mount creates friction against the arm and should NOT be lubricated Remove wing nut from strobe mount Place the top of the arm against the rubber gasket on the strobe mount Replace t...

Page 13: ..._ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ The stem protruding at the base of the arm snaps into the release handle on the Ikelite housing The stem also provides a convenient location for securing the optional DS Slave Sensor or EV Controller Insert the stem into the release handle Depress the handle s release button and slide the stem fully into the receptor Release the button and it should...

Page 14: ...er settings in half stop increments The EV Controller can be triggered using the built in slave sensor or an optional sync cord can be connected Always carry spare batteries Weak batteries cause many camera and strobe problems Prolong the battery life by recharging the NiMH monthly even when not used Do not discharge the NiMH completely as this can cause permanent damage R RA AP PI ID D U US SE E_...

Page 15: ...ogen air mixture to escape 2 Always rinse the exterior of the Substrobe with fresh water after use The strobe can be cleaned by soaking it in a mild soapy solution Use liquid soap RINSE and DRY the strobe before storage 3 The o ring 01 32 36 is located on the inside rim of the DS1 25 battery pack Keep the o ring and the sealing surfaces clean D DO O N NO OT T stretch the o ring when cleaning It is...

Page 16: ...including but not limited to bulb failure are not covered Except as mentioned above no other warranty expressed or implied applies to this Ikelite product We recommend adding an ALL RISK floater to your homeowner s insurance policy in the event you damage flood or lose your camera or strobe Ikelite warranty does NOT cover customer neglect R RE ET TU UR RN NI IN NG G P PR RO OD DU UC CT TS S F FO O...