background image

2255

B

BAALLLL--SSO

OCCKKEETT  AARRM

M  #

#44008866..6611

The articulating Ikelite ball-socket arm secures the DS51 strobe to the contoured

release handle on an Ikelite Digital Still Housing or SLR Housing. The dual ball sockets on

the arm are especially versatile for macro photography since they adjust independently

for a multitude of strobe mounting positions.

The ball-socket arm #4086.61 utilizes 2.5cm (1") diameter balls. Optional

components are available as referenced on the following page to modify the arm.

M

MO

OU

UN

NTT  SSTTRRO

OBBEE  TTO

O  AARRM

M ________________________________________________________________________________________

bbaallll--ttyyppee

strobe mount is featured at the top of the ball-socket arm. This mount

slides into the underneath side of the strobe body, and permits the use of the ball clamp

at the base of the strobe.

If another mount is already secured underneath the strobe, loosen the screw and

remove the original mount from the strobe. On the ball-type strobe mount, there is a

screw opening at each end. Select the side that has the screw opening nearest the center,

slide this end into the base of the strobe, and secure with the screw.

M

MO

OU

UN

NTT  AARRM

M  TTO

O  H

HO

OU

USSIIN

NGG ____________________________________________________________________________________

The stem protruding at the base of the arm snaps into the release handle on the

Ikelite housing. The stem also provides a convenient location for securing the optional

DS Slave Sensor or EV-Controller.

Insert the stem into the release handle. Depress the handle's release button and

slide the stem fully into the receptor. Release the button and it should spring back to

the original position locking the arm in place.

BBAALLLL  CCLLAAM

MPPSS ______________________________________________________________________________________________________________

Loosen the wing nut on the ball clamps to adjust the positioning of the arm. Each

section pivots and rotates 360° before tightening the wing nut.

The center cap limits the movement of the wing nut so that the arm cannot be

accidentally disassembled. Adjust the center cap as desired.

2266

I

IKKEELLIITTEE  BBAALLLL--SSO

OCCKKEETT  CCO

OM

MPPO

ON

NEEN

NTTSS

BBAALLLL--SSO

OCCKKEETT  CCO

OM

MPPO

ON

NEEN

NTTSS                                                                                                                                                                                          

This page illustrates the range of

interchangeable components available

to add onto the Ikelite Ball-Socket

Arm #4086.61.

Note: Tray mounts are offered for

Ikelite, Univeral, and Dovetail systems. 

A variety of Ikelite arm component utilizing 2.5cm (1”) or 3.2cm (1.25”) diameter

balls are available and can be combined with the ball-socket systems of TLC, Nikon, and

Ultralight that use 2.5cm (1”) balls. See “Ikelite Ball-Socket Components” on page 23 for

more information.

A           B           C         D          E            F             G         H           I          J         K        L

Summary of Contents for DS-125

Page 1: ...nos 1 5mm or SLR 20mm with diffuser G Gu ui id de e N Nu um mb be er r I IS SO O 1 1 0 00 0 f fe ee et t 64 surface 32 underwater G Gu ui id de e N Nu um mb be er r I IS SO O 1 1 0 00 0 m me et te er rs s 20 surface 1 0 underwater F Fi ir ri in ng g M Mo od de es s TTL Auto Manual 1 2 M 1 4 M 1 8 M Slave featuring auto exposure using optional DS Sensor 41 00 5 Slave featuring 1 0 manual power sett...

Page 2: ...sual ready light indicates when strobe has recycled Female Ikelite bulkhead connector accepts different camera sync cords the Ikelite DS Sensor 41 00 5 or EV Controller 41 00 6 Exposure guide label references recommended exposure settings Separate diffuser provides softer lighting and wider coverage angle Strobe mount accommodates most Ikelite arm systems B BE EC CO OM MI IN NG G F FA AM MI IL LI ...

Page 3: ...e has provided proper exposure This green confidence light illuminates only in the TTL exposure mode F FI IR RI IN NG G M MO OD DE E S SW WI IT TC CH H_ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ Multiple firing modes are featured TTL Auto and four manual power settings Full 1 2 1 4 and 1 8 T TT TL L A...

Page 4: ...the strobe or the NiMH pack We suggest storage of your strobe with the locking lever OPEN to allow any hydrogen air mixture to escape O O R RI IN NG G _ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ The o ring is located on the inside rim of the NiMH pack Keep the...

Page 5: ...ch is in the TEST position It is normal for the modeling light to flicker every few seconds as the strobe capacitors recharge The momentary power drain on the batteries causes the flickering as the strobe recycles B BU UL LB B_ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _...

Page 6: ...rds the Smart Charger will automatically switch to provide a trickle maintenance charge Only the Smart Charger is capable of providing a trickle maintenance charge permitting the NiMH pack to be continuously charged for extended periods C CO ON NT TI IN NU UO OU US S i il ll lu um mi in na at te ed d l li ig gh ht t Indicates that the NiMH module is being quick charged S SL LO OW W B BL LI IN NK K...

Page 7: ...uence too quick for the Ikelite DS Sensor to identify proper auto exposure and the Ikelite EV Controller 41 00 6 would then be recommended instead For maximum control using manual exposure choose the optional Ikelite EV Controller 41 00 6 which connects to the DS1 25 strobe and provides 1 0 manual power settings in half stop increments The EV Controller can be triggered using the built in slave se...

Page 8: ...e Substrobe has recycled and is ready to fire If the Ikelite housing does not feature TTL compatible circuitry then the ready light in the camera viewfinder would not be triggered when the strobe has recycled T Tr ri ig gg ge er re ed d v vi ia a S Sl la av ve e S Se en ns so or r When using the DS1 25 strobe with the optional DS Sensor or EV Controller without optional sync cord the strobe is not...

Page 9: ...e camera D DO O N NO OT T leave the sync cord or sensor connected to the strobe for prolonged periods as electrolysis can make removal impossible D DO O N NO OT T disconnect the sync cord or sensor from the strobe while underwater or when wet Connections are NOT waterproof when not connected C CO ON NN NE EC CT TI IO ON N T TO O S ST TR RO OB BE E_ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _...

Page 10: ... __ __ __ __ __ __ __ _ 4 41 10 03 3 5 51 1Single strobe cord 4 41 10 03 3 5 52 2 Dual strobe cord These cords connect Ikelite Substrobes to Ikelite camera housings Use TTL Auto or manual exposure modes C Co on nn ne ec ct t I Ik ke el li it te e H Ho ou us si in ng g 1 Make sure all components are dry Clean and lightly lubricate the stem o ring and the housing connector threads Check the o ring f...

Page 11: ...fuser so the tabs on the front lock the diffuser in place 3 To remove the diffuser rotate the diffuser so the cut outs align with the tabs on the front Grasp the protruding ears on the diffuser to remove 4 A lanyard can be attached to the diffuser by threading it thru the two circular openings on the diffuser U US SE E O OF F T TH HE E D DI IF FF FU US SE ER R_ __ __ __ __ __ __ __ __ __ __ __ __ ...

Page 12: ...atured on the DS1 25 and secures to most Ikelite arm systems The paddle type mount is required for compatibility with the arm 4075 1and it allows the strobe to tilt forward and backward The rubber gasket on the strobe mount creates friction against the arm and should NOT be lubricated Remove wing nut from strobe mount Place the top of the arm against the rubber gasket on the strobe mount Replace t...

Page 13: ..._ __ __ __ __ __ __ __ __ __ __ __ __ __ __ __ _ The stem protruding at the base of the arm snaps into the release handle on the Ikelite housing The stem also provides a convenient location for securing the optional DS Slave Sensor or EV Controller Insert the stem into the release handle Depress the handle s release button and slide the stem fully into the receptor Release the button and it should...

Page 14: ...er settings in half stop increments The EV Controller can be triggered using the built in slave sensor or an optional sync cord can be connected Always carry spare batteries Weak batteries cause many camera and strobe problems Prolong the battery life by recharging the NiMH monthly even when not used Do not discharge the NiMH completely as this can cause permanent damage R RA AP PI ID D U US SE E_...

Page 15: ...ogen air mixture to escape 2 Always rinse the exterior of the Substrobe with fresh water after use The strobe can be cleaned by soaking it in a mild soapy solution Use liquid soap RINSE and DRY the strobe before storage 3 The o ring 01 32 36 is located on the inside rim of the DS1 25 battery pack Keep the o ring and the sealing surfaces clean D DO O N NO OT T stretch the o ring when cleaning It is...

Page 16: ...including but not limited to bulb failure are not covered Except as mentioned above no other warranty expressed or implied applies to this Ikelite product We recommend adding an ALL RISK floater to your homeowner s insurance policy in the event you damage flood or lose your camera or strobe Ikelite warranty does NOT cover customer neglect R RE ET TU UR RN NI IN NG G P PR RO OD DU UC CT TS S F FO O...

Reviews: