30
1.
Select "ADJUST MODE" under the panel configuration menu.
2.
On the character indicator, "POS1" is indicated at the upper section and
"POS2" at the lower section.
3.
Align the IRIS position to the OPEN end and press the rotary switch.
("POS1" indicated at the upper section of the character indicator changes to "OK.")
4.
Align the IRIS position to the CLOSE end and press the rotary switch.
("POS2" indicated at the lower section of the character indicator changes to "OK.")
5.
Two seconds after both upper and lower sections of the character indicator
indicate "OK," the upper section changes to "EXE?" and the lower section
changes to "NO" on the indicator.
6.
When the rotary switch is rotated and operated, Yes and No can be switched. To
finalize the setting, select "Yes." To cancel, select "No." Then, press the rotary switch.
7.
When "YES" is selected, execute the IRIS ADJUST setting. The panel restarts.
When "No" is selected, the panel returns to the top page of the panel configuration.
7.5 Program Number Indication
Select "PROGRAM No.," under the panel configuration menu. This sets the program
number to be displayed on the camera number indicator. Settings are OFF (to hide)
and to 1 to 99.
In addition by using the panel configuration "PROGRAM MODE," the program
number indication mode can be set.
FIX mode (OCP fixed)
The OCP sets the program number indication regardless of the camera head
and BS/CCU.
CAM Mode (CAMERA prioritized)
The number memorized in the camera head is prioritized for the program
number indication. At the time of power supply start-up or at the indication
mode setting, the indication of the camera number indicator of OCP is
changed according to the answer from the camera head and BS/CCU. When
there is no answer, the number memorized in OCP is indicated.
To enable the BS/CCU program number function, set to the CAM mode.
OCP mode (OCP prioritized)
The number memorized in the OCP is prioritized for the program number
indication. At the time of power supply start-up and at the indication mode
setting, the number memorized in the OCP is indicated on the camera number
indicator. In addition, the number is sent to the camera head.
Summary of Contents for OCP-10
Page 1: ...OCP 10 Operation Control Panel Operation Manual Products conforming to RoHS directive...
Page 2: ......
Page 10: ...SAFETY PRECAUTIONS...
Page 12: ......
Page 16: ......
Page 18: ...2 1 3 External View 1 VR TYPE Option...
Page 19: ...3 2 Slim TYPE...
Page 20: ...4 3 JS TYPE Option...
Page 59: ...43 10 Changing Information...
Page 60: ......
Page 62: ......