IKA CBC 5 basic Operating Instructions Manual Download Page 13

13

 Basic guide to setting the menu options:

F

 Enter the menu by pressing ”Menu” key (G)�

F

 Turn the left knob (K) to select a menu option�

F

 Turn the right knob (J) to change the menu value settings�

F

 Confirm the menu settings by pressing the right knob (J)�

 Operating mode (MODE):

Mode A:

 After power on/power failure no automatic re-

start of functions�

Mode B:

 After power on/power failure automatic restart 

of functions, depending on previous settings�

Mode C:

 Set values (set in A or B) cannot be changed�

After power on/power failure automatic restart of func-
tions, depending on previous settings�

 Maximum temperature (HI T):

The maximum adjustable value: 200° C� This value can be 
limited additionally by the selected fluid (No�, see “Fluid 
(Standard information for 

IKA

®

 fluid)” fluid type)�

Note: 

The maximum value is limited by the set safety 

temperature�

 Minimum temperature (LO T):

The minimum adjustable value: -25° C

 Maximum speed (HI R):

The maximum adjustable value: 4600 rpm�

 Minimum speed (LO R):

The minimum adjustable value: 1000 rpm

 Fluid type

 (

FLUI

)

The chosen fluid (No�) of the temperature setting is lim-
ited� See Section “

Fluid

”�

 Temperature control type (AUTO) (heating):

AUTO 1:

 

AUTO 1 is the default setting� The optimum settings are 
determined automatically�

Heating up curve in auto-tuning control (Auto 1):

°C

t

Fig. 12

AUTO 0:

For special requirements, AUTO 0 can be used with man-
ual adjustment of the control parameters�

If the PID control (AUTO 0) option is selected, the follow-
ing items including 

Kp 1

Ti 1

 and 

Td 1

 could be set� 

Otherwise they are not displayed in the menu list�

Note: 

Inappropriate settings may produce the following 

heating up curves:

Fig. 13

°C

t

Kp too high

°C

t

Ti too low

°C

t

Td too high

°C

t

Kp too low
Ti too high

Summary of Contents for CBC 5 basic

Page 1: ...20000013102 IKA CBC 5 basic CBC 5 basic_112016 Operating instructions EN...

Page 2: ...er 4 Handle 5 Venting grid 6 Mains switch 7 Power socket 8 Cable clip 9 Pump connection IN 10 Pump connection OUT 11 RS 232 interface 12 USB interface 13 External temperature sensor socket Device setu...

Page 3: ...panel and display 10 Setting the safety temperature 11 Commissioning 11 Menu settings 12 Menu structure 12 Basic guide to setting the menu options 13 Operating mode MODE 13 Maximum temperature HI T 13...

Page 4: ...10 2 051 EN 61326 1 EN 60529 and DIN 12876 1 Indicates an extremly hazardous situation which if not avoided will result in death serious injury Indicates a hazardous situation which if not avoided can...

Page 5: ...For example users can implement measures that inhibit fire or explo sions or comprehensive monitoring equipment Process pathogenic material only in closed vessels under a suitable fume hood Please co...

Page 6: ...at also supplies residential areas The safety of the user cannot be guaranteed if the device is operated with accessories that are not sup plied or recommended by the manufacturer if the device is ope...

Page 7: ...ources and do not expose to sun light Cooling machine pump motor and electronics produce intrinsic heat that is dissipated via the venting grids 5 Never cover these venting grids Note After setting up...

Page 8: ...valve is closed Ro tate clockwise to the stop position see Fig 7 Note Please note information in chapter Commissioning Connect the mains plug and turn on the device with mains switch 6 The low level...

Page 9: ...distilled or bi distilled water are unsuitable for operation due to corrosive properties of these media High purity water and distillates are suitable as a medium after adding 0 1 g soda Na2 CO3 sodi...

Page 10: ...speed value Start stop the pump function K Rotating pressing knob Set the temperature value Start stop the heating refrigerating function Navigation selecting the settings in the menu Set and confirm...

Page 11: ...and fan starts to run at once After pressing the mains switch 6 the start up of the com pressor is delayed about 3min In working status press the right knob J to stop the pump function The heating ref...

Page 12: ...play will change back and show pump speed When the heating refrigerating function is activated you can enter the menu option by pressing menu key G about 3 seconds Menu settings MODE Maximum temperatu...

Page 13: ...luid fluid type Note The maximum value is limited by the set safety temperature Minimum temperature LO T The minimum adjustable value 25 C Maximum speed HI R The maximum adjustable value 4600 rpm Mini...

Page 14: ...not displayed in the menu list The sampling time EuT 2 s is the interval over which the external control deviation and the respective control variable dependent on Kp 2 Ti 2 Td 2 Df t and FAST is dete...

Page 15: ...cs of the interface and the al location of signal status standard RS 232 applies in accor dance with DIN 66 259 Part 1 Transmission procedure asynchronous character transmis sion in start stop mode Ty...

Page 16: ...ODE_1 Set to External temperature control OUT_WD1 n Start the watchdog mode 1 and set the time for the watchdog to n 20 1500 seconds Echo of the Watchdog time During a WD1 event the heating and pump f...

Page 17: ...erial Water containing tenside isopropyl alcohol Cosmetics Water containing tenside isopropyl alcohol isopropyl alcohol Water containing tenside Foodstuff Water containing tenside Fuel Water containin...

Page 18: ...off Heating refrigerating off Device internal temperature is too high Check the ambient temperature and let the device cool down Err 10 Pump off Heating refrigerating off PC communication failure Chec...

Page 19: ...be nominal width 12 mm H PUR 8 PUR tube nominal width 8 mm H PUR 12 PUR tube nominal width 12 mm H FKM 8 FKM tube nominal width 8 mm H FKM 12 FKM tube nominal width 12 mm Tubing insulations ISO 8 Insu...

Page 20: ...play LED Heating capacity W 2500 230 VAC 1250 115 VAC Cooling capacity according to DIN 12876 at 4600 rpm 20 C 10 C 0 C 10 C 20 C W 350 400 W at 3200 rpm 320 370 W at 3200 rpm 270 320 W at 3200 rpm 19...

Page 21: ...IKA warranty conditions the warranty period is 24 months For claims under the warranty please contact your local dealer You may also send the machine direct to our factory enclosing the delivery invo...

Page 22: ...IKA Werke GmbH Co KG Janke Kunkel Str 10 D 79219 Staufen Tel 49 7633 831 0 Fax 49 7633 831 98 sales ika de www ika com...

Reviews: