TROUBLESHOOTING
Rev. : 09/25/2012
21
Dualhead Cross- Repeater
The Cross Repeater look the same for the Local and the remote placement. Because of
internal jumper settings the data direction is fixed. Please note to install the device, marked
with „Cross Repeater Local CATX“ at a position where the CATx cable link to the Local
Unit and the device, marked with „Cross Repeater Remote CATx“ at a position where the
CATx cable link to the Remote Unit.
5. Troubleshooting
Monitor
There isn’t a picture.
Check the power supply connection at the local and remote unit and at the
Repeater/Cross- Repeater. Is the Power (Red LED) at the devices illuminated (see
page 15)? If not, the internal power-supply may be damaged or there may be an
internal error.
Check that the INTERCONNECT cable is connected at the Local Unit and the
Remote Unit and at the Repeater/Cross- Repeater. Is the Link Status LED
illuminated (see page 15)? If not, there may be a problem with the Interconnection
cable: