background image

U Series

Fan Forced 

Ceiling Mounted Heater

WHEN USING ELECTRIC APPLIANCES, BASIC PRECAU-
TIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE
RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PER-
SONS, INCLUDING THE FOLLOWING:

1.

Read all instructions before installing or using this heater.

2. This  heater  is  hot  when  in  use. To  avoid  burns,  do  not  let

bare  skin  touch  hot  surfaces.  Keep  combustible  materials,
such as furniture, pillows, bedding, papers, clothes, etc. and
curtains at least 3 feet (0.9 m) from the front of the heater.

3. Extreme caution is necessary when any heater is used by or

near  children  or  invalids  and  whenever  the  heater  is  left
operating and unattended.

4. Do not operate any heater after it malfunctions. Disconnect

power at service panel and have heater inspected by a rep-
utable electrician before using.

5. Do not use outdoors.

6. To disconnect heater, turn controls to off, and turn off power

to heater circuit at main disconnect panel.

7.

Do not insert or allow foreign objects to enter any ventilation
or exhaust opening as this may cause an electric shock, fire,
or damage to the heater.

8. To prevent a possible fire, do not block air intake or exhaust

in any manner.

9. A heater has hot and arcing or sparking parts inside. Do not

use  it  in  areas  where  gasoline,  paint,  or  flammable  liquids
are used or stored.

10. Use this heater only as described in this manual.  Any other

use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.

11. This heater is provided with a red alarm light that will illumi-

nate  only  if  the  heater  has  turned  off  as  a  result  of  over-
heating. If you see the light on, immediately turn the heater
off and inspect for any objects on or adjacent to the heater
that may have blocked the airflow or otherwise caused high
temperatures  to  have  occurred. 

DO  NOT  OPERATE THE

HEATER WITH THE ALARM LIGHT ILLUMINATING.

12. This heater is intended for comfort heating applications and

not intended for use in special environments. Do not use in
damp or wet locations such as marine or greenhouse or in
areas where corrosive or chemical agents are present.

13. When  installing,  see  INSTALLATION  INSTRUCTIONS  for

additional warnings and precautions.

14. For safe and efficient operation, and to extend the life of your

heater,  keep  your  heater  clean  -  See  MAINTENANCE
INSTRUCTIONS.

SAVE THESE INSTRUCTIONS

!

Installation, Operation & Maintenance Instructions

WARNING

IMPORTANT INSTRUCTIONS

PPD 41511

12/14

5200-11226-000

Specifications

MODEL

CATALOG

WIRE

NO.

NO.

VOLTS AMPS

WATTS

BTU/HR

SIZE

U1000FA

QCH1101

120

8.4

1000

3413

14AWG

4.2

500

1706

U1500FA QCH1151

120

12.5

1500

5120

12AWG

6.25

750

2560

240

8.4

2000

6826

14AWG

U2004FA QCH1202

4.2

1000

3413

208

7.3

1500

5120

14AWG

3.62

750

2560

277

7.2

2000

6826

14AWG

U2007FA QCH1207

3.6

1000

3413

240

6.3

1500

5120

14AWG

3.1

750

2560

Conforms to ANSI/UL2021

and CSA C22.2 No. 46.

Summary of Contents for U1000FA

Page 1: ...nly as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 11 This heater is provided with a red alarm light that will illumi nate only if the heater has turned off as a result of over heating If you see the light on immediately turn the heater off and inspect for any objects on or adjacent to the heater that may have blocke...

Page 2: ...ruction 1 Carefully mark and cut a hole measuring 9 3 8 235mm wide by 11 1 8 283mm long One edge of the hole must be cut along the edge of a joist 2 Proceed to No 1 through 6 Installation of Back Box in New Construction To prevent a possible fire injury to persons or damage to the heater adhere to the following 1 Disconnect all power coming to heater at main service panel before wiring or servicin...

Page 3: ...ect the black supply lead to the heaters black pigtail lead For 208 and 240 volt heaters change the color of the heaters white pigtail lead to black by wrapping with black electrical tape Most electri cal codes require the supply leads to be conneced to black leads Then connect the two black supply leads to the two black receptacle leads Connect the two red thermostat leads to thermostat as shown ...

Page 4: ... ture limit control that will automatically turn the heater off to pre vent a fire if the heater overheats If heater cycles off on this con trol a red alarm light will illuminate MAINTENANCE INSTRUCTIONS It is important to keep this heater clean Your heater will give you years of service and comfort with only minimum care To assure efficient operation follow the simple instructions below User Clea...

Page 5: ... WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT WHETHER BASED UPON NEGLIGENCE TORT S...

Page 6: ...6 Notes Notas Notes ...

Page 7: ... lo utilice en áreas en las que se utilice o almacene gasolina pintura o líquidos inflamables 10 Utilice este calefactor únicamente de la manera descrita en este manu al Cualquier otra forma de uso no recomendada por el fabricante puede ser causa de incendio choque eléctrico o daños personales 11 Este calefactor cuenta con una luz de alarma roja que se ilumina única mente si el calefactor se ha ap...

Page 8: ... los bordes del agujero debe cortarse a lo largo del borde de una viga 2 Realice los pasos N 1 al 6 Instalación de la caja posterior en una construcción nueva Para evitar un posible incendio lesiones personales o daños al calefactor observe lo siguiente 1 Antes de proceder a tareas de conexionado o de reparación del calefactor desconecte toda la alimentación eléctrica que llega al mismo desde el t...

Page 9: ...l color del conductor flexible blanco del calefactor a negro envolviéndolo en cinta eléctrica negra La mayoría de los códigos eléctricos requieren que los cables de conexión de alimentación se conecten a cables de conexión negros Luego conecte los dos cables de conexión de alimentación negros a los dos cables de conexión de tomacorriente negros Conecte los dos cables de conexión de termostato rojo...

Page 10: ...ue la temperatura de la habitación disminuya bien por debajo del punto de congelación Aviso operacional Su calefactor está equipado con un control de límite de sobretemperatu ra con reposición automática que lo apagará automáticamente para impedir su sobrecalentamiento que podría provocar un incendio INSTRUCCIONES DE MANTENIMIENTO Es importante mantener limpio este calefactor Su calefactor le brin...

Page 11: ...XPRESA O IMPLÍCITA Y POR LA PRESENTE SE DECLINA Y EXCLUYE DE ESTE ACUERDO TODA GARANTÍA IMPLÍCITA DE COMERCIABILIDAD Y ADECUACIÓN A UN PROPÓSITO PARTICULAR QUE EXCEDA LAS GARANTÍAS EXPRESAS ANTEDICHAS MARLEY ENGINEERED PRODUCTS NO SE HARÁ RESPONSABLE POR DAÑOS CONSIGUIENTES QUE SE PRODUZCAN CON RESPECTO AL PRODUCTO EN BASE YA SEA A NEGLIGENCIA AGRAVIO RESPONSABILIDAD ESTRICTA O CONTRATO Algunos es...

Page 12: ...ou des étincelles électriques Ne l utilisez pas dans des zones où de l essence ou des liquides inflammables sont util isés ou entreposés 10 N utilisez ce radiateur que comme c est décrit dans ce manuel Toute autre utilisation non recommandée par le constructeur peut causer un départ d incendie une commotion électrique ou des blessures corporelles 11 Ce radiateur est fourni avec un voyant rouge d a...

Page 13: ...u radiateur Vor la Figure 1 Positionnement du boîtier arrière dans une construction existante 1 Découpez soigneusement une ouverture de 9 3 8 235 mm de large sur 11 1 8 283 mm de long Un bord de l ouverture doit être coupé le long du côté d une solive 2 Effectuez les étapes 1 à 6 précédentes Installation de boîtier arrière dans une construction neuve Pour éviter un possible départ d incendie des b...

Page 14: ...ateurs en 208 et 240 volts changez la couleur du fil blanc du radiateur en noir en entourant son extrémité avec de la bande adhésive noire d électricien la plupart des normes électriques exigent que les fils d alimentation soient reliés à des fils noirs Puis branchez les deux fils d alimentation noirs sur les deux fils noirs du réceptacle Branchez les deux fils rouges de thermostat au thermostat c...

Page 15: ...otection automatique con tre un dépassement de température qui coupe automatiquement le radi ateur pour éviter un départ d incendie en cas de surchauffe INSTRUCTIONS D ENTRETIEN Il est important de garder propre le radiateur Votre radiateur vous fourni ra des années de bon service et de confort avec juste un minimum de soins Pour assurer son fonctionnement efficace suivez les instructions simples ...

Page 16: ...CÈDENT TIENNENT LIEU DE TOUTES LES AUTRES GARANTIES EXPLICITES OU IMPLICITES ET TOUTES LES GARANTIES IMPLICITES DE VALEUR MARCHANDE ET D ADÉQUATION POUR UNE FINALITÉ SPÉCIFIQUE QUI EXCÉDERAIENT LES DISPOSITIONS DE GARANTIE PRÉCÉDEMMENT ÉNONCÉES SONT ICI REJETÉES ET EXCLUES DE CET ACCORD MARLEY ENGINEERED PRODUCTS NE SERA PAS TENU POUR RESPON SABLE DES DOMMAGES CONSÉCUTIFS SURVENANT EN RELATION AVE...

Reviews: