Installation of Heater in T-Bar Ceiling 
Using Frame Kit Model HTBF

1. Determine the desired location for the heater.

2. Remove heater from carton, remove front cover, heater

assembly from back box.

3. Remove T-Bar frame, envelope containing mounting screws

from carton.

4.  Mount the heater backbox to the HTBF kit frame using the

four screws provided.  Refer to figure 2.

5.  Place the HTBF frame with heater backbox installed in ceil-

ing framing and secure in position.  Secure the frame to the
building structure as necessary using appropriate wire to pre
vent the heater and frame from falling.

6.  Bring power supply cable to heater location. Remove the

desired knockout in backbox and install cable using an
appropriate cable clamp, leaving at least six inches (153mm)
of wire in box for connections.

NOTE:

Power supply cable must enter backbox in location

behind the disconnect switch assembly.

7.  Complete the installation by following the steps in the "Wiring

of heater" and "Installation of Front Cover(Grille)" sections."

Field Conversion for Lower Wattage

NOTE:

Refer to specification chart for lower wattage ratings

which are available.

To convert heater to lower wattage rating, completely remove red
jumper wire from both heating elements (See Figure 3).  Discard
this jumper.  Be sure remaining wires are securely connected.

Wiring of Heater

1. Following wiring diagram (Figure 4) connect supply wiring

and thermostat wiring to heater lead wires in back box.

NOTE:  

For 120 and 277 volt heaters connect the white neutral

supply lead to the heaters white pigtail lead, and connect the
black supply lead to the heaters black pigtail lead.  For 208 and
240 volt heaters change the color of the heaters white pigtail
lead to black by wrapping with black electrical tape. (Most electri-
cal codes require the supply leads to be conneced to black
leads).  Then connect the two black supply leads to the two
black receptacle leads.  Connect the two red thermostat leads to
thermostat as shown in wiring diagram.

2. Insert wiring plug from heater/fan assembly into socket in

back box.

3. Fit heater/fan assembly into back box and secure in place

with (2) screws provided through the center slots in the fan
assembly.

NOTE:  

Use the screws provided by the factory to install

heater/fan assembly to the back box.

4. Turn disconnect switch mounted on heater/fan assembly

“ON”.

INSTALLATION OF FRONT COVER (GRILLE) 

1. Mount grille over brackets at the top of the heater. Sheet

metal tabs at the top end of the grille hook onto the brackets
at the top end of the heater’s fan panel assembly.

2. Insert screw through bottom hole on the grille. The screw with

thread into the backbox. Tighten the screw until the grille is
flush to the ceiling or mounting frame. BE CAREFUL NOT TO
OVER TIGHTEN.

RISK  OF  FALLING  –  THE  HEATER  BACKBOX  MUST  BE
SECURELY MOUNTED TO THE BUILDING STRUCTURE AND
THE  BUILDING  STRUCTURE  MUST  BE  CAPABLE  OF  SUP-
PORTING  THE  HEATER  WITH  ALL  ACCESSORIES.    THE
HEATER WEIGHT WITH ACCESSORIES IS AT LEAST 18 LBS
(18.2 KG).

3

Figure 2

Figure 3

Remove red jumper
for lower wattage
rating

1

2

3

4

1

2

3

4

Disconnect
Switch
Assembly

Over-
Temperature
Limit

Fan Delay Control

Elements

Fan Motor

Red Jumper
(Remove for half wattage)

L1

L2

Tstat leads (Red)

G

Power leads
(Black & White)

Alarm
Light

Figure 4 - Wiring Diagram

FIELD WIRING

FACTORY WIRING

HTBF Frame

Back box

Summary of Contents for U1000FA

Page 1: ...nly as described in this manual Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 11 This heater is provided with a red alarm light that will illumi nate only if the heater has turned off as a result of over heating If you see the light on immediately turn the heater off and inspect for any objects on or adjacent to the heater that may have blocke...

Page 2: ...ruction 1 Carefully mark and cut a hole measuring 9 3 8 235mm wide by 11 1 8 283mm long One edge of the hole must be cut along the edge of a joist 2 Proceed to No 1 through 6 Installation of Back Box in New Construction To prevent a possible fire injury to persons or damage to the heater adhere to the following 1 Disconnect all power coming to heater at main service panel before wiring or servicin...

Page 3: ...ect the black supply lead to the heaters black pigtail lead For 208 and 240 volt heaters change the color of the heaters white pigtail lead to black by wrapping with black electrical tape Most electri cal codes require the supply leads to be conneced to black leads Then connect the two black supply leads to the two black receptacle leads Connect the two red thermostat leads to thermostat as shown ...

Page 4: ... ture limit control that will automatically turn the heater off to pre vent a fire if the heater overheats If heater cycles off on this con trol a red alarm light will illuminate MAINTENANCE INSTRUCTIONS It is important to keep this heater clean Your heater will give you years of service and comfort with only minimum care To assure efficient operation follow the simple instructions below User Clea...

Page 5: ... WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT WHETHER BASED UPON NEGLIGENCE TORT S...

Page 6: ...6 Notes Notas Notes ...

Page 7: ... lo utilice en áreas en las que se utilice o almacene gasolina pintura o líquidos inflamables 10 Utilice este calefactor únicamente de la manera descrita en este manu al Cualquier otra forma de uso no recomendada por el fabricante puede ser causa de incendio choque eléctrico o daños personales 11 Este calefactor cuenta con una luz de alarma roja que se ilumina única mente si el calefactor se ha ap...

Page 8: ... los bordes del agujero debe cortarse a lo largo del borde de una viga 2 Realice los pasos N 1 al 6 Instalación de la caja posterior en una construcción nueva Para evitar un posible incendio lesiones personales o daños al calefactor observe lo siguiente 1 Antes de proceder a tareas de conexionado o de reparación del calefactor desconecte toda la alimentación eléctrica que llega al mismo desde el t...

Page 9: ...l color del conductor flexible blanco del calefactor a negro envolviéndolo en cinta eléctrica negra La mayoría de los códigos eléctricos requieren que los cables de conexión de alimentación se conecten a cables de conexión negros Luego conecte los dos cables de conexión de alimentación negros a los dos cables de conexión de tomacorriente negros Conecte los dos cables de conexión de termostato rojo...

Page 10: ...ue la temperatura de la habitación disminuya bien por debajo del punto de congelación Aviso operacional Su calefactor está equipado con un control de límite de sobretemperatu ra con reposición automática que lo apagará automáticamente para impedir su sobrecalentamiento que podría provocar un incendio INSTRUCCIONES DE MANTENIMIENTO Es importante mantener limpio este calefactor Su calefactor le brin...

Page 11: ...XPRESA O IMPLÍCITA Y POR LA PRESENTE SE DECLINA Y EXCLUYE DE ESTE ACUERDO TODA GARANTÍA IMPLÍCITA DE COMERCIABILIDAD Y ADECUACIÓN A UN PROPÓSITO PARTICULAR QUE EXCEDA LAS GARANTÍAS EXPRESAS ANTEDICHAS MARLEY ENGINEERED PRODUCTS NO SE HARÁ RESPONSABLE POR DAÑOS CONSIGUIENTES QUE SE PRODUZCAN CON RESPECTO AL PRODUCTO EN BASE YA SEA A NEGLIGENCIA AGRAVIO RESPONSABILIDAD ESTRICTA O CONTRATO Algunos es...

Page 12: ...ou des étincelles électriques Ne l utilisez pas dans des zones où de l essence ou des liquides inflammables sont util isés ou entreposés 10 N utilisez ce radiateur que comme c est décrit dans ce manuel Toute autre utilisation non recommandée par le constructeur peut causer un départ d incendie une commotion électrique ou des blessures corporelles 11 Ce radiateur est fourni avec un voyant rouge d a...

Page 13: ...u radiateur Vor la Figure 1 Positionnement du boîtier arrière dans une construction existante 1 Découpez soigneusement une ouverture de 9 3 8 235 mm de large sur 11 1 8 283 mm de long Un bord de l ouverture doit être coupé le long du côté d une solive 2 Effectuez les étapes 1 à 6 précédentes Installation de boîtier arrière dans une construction neuve Pour éviter un possible départ d incendie des b...

Page 14: ...ateurs en 208 et 240 volts changez la couleur du fil blanc du radiateur en noir en entourant son extrémité avec de la bande adhésive noire d électricien la plupart des normes électriques exigent que les fils d alimentation soient reliés à des fils noirs Puis branchez les deux fils d alimentation noirs sur les deux fils noirs du réceptacle Branchez les deux fils rouges de thermostat au thermostat c...

Page 15: ...otection automatique con tre un dépassement de température qui coupe automatiquement le radi ateur pour éviter un départ d incendie en cas de surchauffe INSTRUCTIONS D ENTRETIEN Il est important de garder propre le radiateur Votre radiateur vous fourni ra des années de bon service et de confort avec juste un minimum de soins Pour assurer son fonctionnement efficace suivez les instructions simples ...

Page 16: ...CÈDENT TIENNENT LIEU DE TOUTES LES AUTRES GARANTIES EXPLICITES OU IMPLICITES ET TOUTES LES GARANTIES IMPLICITES DE VALEUR MARCHANDE ET D ADÉQUATION POUR UNE FINALITÉ SPÉCIFIQUE QUI EXCÉDERAIENT LES DISPOSITIONS DE GARANTIE PRÉCÉDEMMENT ÉNONCÉES SONT ICI REJETÉES ET EXCLUES DE CET ACCORD MARLEY ENGINEERED PRODUCTS NE SERA PAS TENU POUR RESPON SABLE DES DOMMAGES CONSÉCUTIFS SURVENANT EN RELATION AVE...

Reviews: