OPERATING
INSTRUCTIONS
1. Heater must be properly installed before operation.
2. Rotate wall thermostat knob counterclockwise until control
stops. This is the minimum heat setting.
3. Turn power supply to heater “ON” at main switch panel.
4. Heater should not operate. If it operates, disconnect power
and re-check wiring.
5. Rotate wall thermostat knob clockwise until it stops (maxi-
mum heat setting) and wait at least 2 minutes. Fan control
will delay fan coming on until element is warm.
6. If heater and fan do not come on, disconnect power and
check wiring.
7. Allow heater to continue to operate until room temperature
reaches desired comfort level. Then rotate wall thermostat
knob counterclockwise slowly until thermostat clicks off. Fan
must continue to operate for a minute or so until element
cools. If fan turns off immediately when thermostat is turned
off, disconnect power and check wiring. (See Fan Delay
Notice).
8. It may be necessary to readjust thermostat a time or so until
exact comfort level is attained. Rotation in the clockwise
direction will increase the amount of time the heater will pro-
duce heat. Rotation in the counterclockwise direction will
reduce the amount of time the heater is on.
NOTE:
For best results, the heater should be left “ON” constant-
ly during the heating season as the thermostat, when properly
set, will maintain the desired temperature. In the full counter-
clockwise position the heater will remain off until the room tem-
perature drops well below freezing.
Operational Notice:
Your heater is equipped with an automatic reset over-tempera-
ture limit control that will automatically turn the heater off to pre-
vent a fire if the heater overheats. If heater cycles off on this con-
trol, a red alarm light will illuminate.
MAINTENANCE
INSTRUCTIONS
It is important to keep this heater clean. Your heater will give you
years of service and comfort with only minimum care. To assure
efficient operation follow the simple instructions below.
User Cleaning Instructions:
1. After the heater has cooled, a vacuum cleaner with brush
attachment may be used to remove dust and lint from exterior
surfaces of the heater including the grille openings.
2. With a damp cloth, wipe dust and lint from grille and exterior
surfaces.
3. Return power to heater and check to make sure it is operat-
ing properly.
Maintenance Cleaning Instructions:
(To be performed only by Qualified Service Personnel)
At least annually, the heater should be cleaned and serviced by
a qualified service person to assure safe and efficient operation.
This should include the removal of the grille and, as necessary
the heater from the backbox to clean residue from the unit. After
completing the cleaning and servicing, the heater should be fully
reassembled and checked for proper operation.
ALL SERVICING BEYOND SIMPLE CLEANING THAT
REQUIRES DISASSEMBLY SHOULD BE PERFORMED BY
QUALIFIED SERVICE PERSONNEL.
CAUTION - DO NOT CONTINUE TO ATTEMPT TO USE THE
HEATER IF THE SAFETY CONTROL REPEATEDLY OPER-
ATES AFTER BEING RESET. TO DO SO COULD PERMA-
NENTLY DAMAGE THE HEATER OR CREATE A FIRE OR
SAFETY HAZARD.
DO NOT TAMPER WITH OR BYPASS ANY SAFETY LIMITS
INSIDE HEATER.
TO REDUCE RISK OF FIRE AND ELECTRIC SHOCK OR
INJURY, DISCONNECT ALL POWER COMING TO HEATER
AT MAIN SERVICE PANEL AND CHECK THAT THE ELEMENT
IS COOL BEFORE SERVICING OR PERFORMING
MAINTENANCE.
4
Summary of Contents for U1000FA
Page 6: ...6 Notes Notas Notes ...