SAFETY PRECAUTIONS AND INSTALLATION GUIDELINES
Rev. : 09/25/2012
5
Safety Precautions and Installation Guidelines
To ensure reliable and safe long-term operation, please note the following installation
guidelines:
•
Do not use CATx-devices to link between buildings – please use fibre devices.
•
Only use in dry, indoor environments.
•
If the building has 3-phase AC power, try to ensure that equipment connected to the
Local and Remote units is on the same phase.
•
Try not to route a CATx link cable alongside power cables.
•
The Repeater/Cross- Repeater and any power supplies can get warm. Do not locate them
in an enclosed space without any airflow.
•
Do not place a power supplies directly on top of a unit.
•
Do not obstruct a unit’s ventilation existing holes.
To safeguard against personal injury and avoid possible
damage to equipment or property, please observe the
following:
•
Only use power supplies originally supplied with the
product or manufacturer-approved replacements. Do not
attempt to dismantle or repair any power supply. Do not
use a power supply if it appears to be defective or has a
damaged case.
•
Connect all power supplies to grounded outlets. In each
case, ensure that the ground connection is maintained
from the outlet socket through to the power supply’s AC
power input.
•
Do not attempt to modify or repair this product, or make
a connection from the interconnection link interface to
any other products, especially telecommunications or
network equipment.