Configuration
2011-10-11
67
5.3
System Settings
5.3.1
System
You can configure the parameters for the system configuration in this
menu.
You have the following possibilities to access the menu:
You can only set a selection of system parameters in the LCD display, in
contrast to the OSD.
You can select between the following settings:
Field
Selection
Description
Name
Text
Insert a name of the configuration in
which the current settings should have to
be saved (default: Name).
Device
Text
Insert the name of the matrix that is
shown in the lower left corner of all
menus (default: SWITCH_01).
Info
Text
Additional text field for the description of
the configuration (default: Factory
settings).
Y
(Yes)
Configuration and remote control of the
sub matrix according to the settings of
the main matrix. No local configuration
opportunity available.
Note:
If the matrix is defined as a sub
matrix, the user automatically loses
control in the OSD. Control can be
gained again, if you open the OSD of the
defined sub matrix again by using the
'Hot Key' command <Shift>, <Shift>,
<s>, <o>.
Sub Matrix
N
(No)
Function not active (default)
Y
(Yes)
Starting the matrix after restart or a
switch-on with the default configuration.
Load Default
N
(No)
Start the matrix after a restart or a
switch-on with the last saved
configuration (default).