4.3.9
Parallel Operation (Stacking)
If you have special configurations, especially at installations with several
monitors per work station or additional support of USB 2.0 transmission
paths, the number of connectable CPUs and consoles can be increased
by a parallel operation (stacking) of several Draco major matrices.
One of the Draco major matrices has to be defined as the
master
matrix,
all of the others have to be configured as
slave
and the IP address of the
master matrix has to be entered in the field
Master IP Address
(see
Chapter 5.3.1, Page 67).
They have to be connected to the master matrix by the network connector
(RJ45) of the CPU board. The option
Enable LAN Echo
has to be
activated at the master matrix (see Chapter 5.3.1, Page 67).
Switching of stacked devices might be delayed by several seconds.