Draco major
144
2011-10-11
7.2.2
Fiber
A point-to-point connection is necessary. Operation with multiple patch
panels is allowed. Routing over active network components, such as
Ethernet Hubs, Matrixes or Routers, is not allowed.
Type of Interconnect Cable (Cable notations according to VDE)
Type of cable
Specifications
Single-mode 9
μ
m
Two fibers 9
μ
m
I-V(ZN)H 2E9 (in-house patch cable)
I-V(ZN)HH 2E9 (in-house breakout cable)
I/AD(ZN)H 4E9 (in-house or outdoor
breakout cable, resistant)
A/DQ(ZN)B2Y 4G9 (outdoor cable, with
protection against rodents)
Multi-mode 50
μ
m
Two fibers 50
μ
m
I-V(ZN)H 2G50 (in-house patch cable)
I/AD(ZN)H 4G50 (in-house or outdoor
breakout cable, resistant)
Multi-mode 62.5
μ
m
Two fibers 62.5
μ
m
I-V(ZN)HH 2G62,5 (in-house breakout
cable)
A/DQ(ZN)B2Y
4G62,5
(outdoor cable,