ihp.us.com
901176-00 NC
5
WARNING: A qualified service person must install
appliance. Follow all local codes.
WARNING: This appliance is equipped for natural
gas. Gas type is indicated on the rating plate. Field
conversion is not permitted.
WARNING: Make sure the selector switch is in the
OFF position before installing appliance.
WARNING: Never install the appliance
• in a recreational vehicle
• where curtains, furniture, clothing or other flammable
objects are less than the minimal distances required
by the manufacturer
• in high traffic areas
• in windy or drafty areas
WARNING: Maintain the minimum clearances. If
you can, provide greater clearances from floor, ceiling
and adjoining wall.
INSTALLATION AND CLEARANCES
CHECK GAS TYPE
Gas type will be indicated on the burner and the box� Do not use a
natural gas burner with propane� If your gas supply is not the cor-
rect gas type, do not install appliance� Call dealer where you bought
appliance for proper type appliance�
INSTALLATION
WARNING: This appliance assembly contains
burner orifices specifically for the input gas specified
on the burner and box, as well as the BTU rating speci-
fied in this manual. Modifying or failure to use the
factory orifice may cause property damage, personal
injury or loss of life.
NOTE:
When installing your gas logs into a manufactured firebox,
follow firebox manufacturer's instructions for minimum clearances
to combustible materials�
NOTICE: Surface temperatures of adjacent walls and
mantels become hot during operation. Walls and
mantels above the firebox may become hot to the
touch. If installed properly, these temperatures meet
the requirement of the national product standard. Fol-
low all minimum clearances shown in this manual.
INSTALLING DAMPER CLAMP ACCESSORY FOR
VENTED OPERATION
NOTE
: Appliance must be installed only in a solid-fuel-burning fire-
place with a working flue and constructed of noncombustible material.
This unit may not be installed in a vented fireplace with a chimney
height less than the minimum required by the manufacturer�
Appliance may be installed as a vented decorative appliance in com-
pliance with ANSI Z21�60�
A permanent free opening must be provided by either the fireplace
chimney or chimney damper to vent carbon monoxide and other
flue gases� Any chimney damper must be fixed in a manner which
will maintain the permanent free opening at all times� Use the Tables
found on
Page 6
(For Factory Built Fireplaces and For Masonry
Built Fireplaces Free Opening Area of Chimney Damper for Venting
Combustion Products From Decorative Appliances For Installation in
Solid Fuel Burning Firplaces) to determine the minimum permanent
free opening based on chimney height and the appliance BTU rating�
The Damper Clamp (
see Figure A
) with bolt is provided as a means
to prevent the full closure of the damper blade� The clamp is easily
attached to most damper blades with pliers or a wrench, and must be
permanently installed� The clamp is designed to prevent accidential
closure of the damper when installed as pictured� Should the clamp
not fit, or fail to provide the required permanent vent opening, do
any of the following:
• Have a permanent stop installed
• Remove the damper blade
• Install a screw or bolt on the edge of the damper
• Weld damper in place
Figure A - Attaching Damper Clamp
Damper
Damper
Clamp
Damper
Damper
Clamp
Damper
Manufactured Fireplace
Masonry Fireplace
LOG SET
MINIMUM FIREPLACE SIZE
WIDTH
DEPTH
HEIGHT
FRONT
REAR
ASHTONWHITEBIRCH24
OZARKCHARREDOAK24
SMOKYWEATHEREDOAK24
36"
24"
18"
24"
ASHTONWHITEBIRCH30
OZARKCHARREDOAK30
SMOKYWEATHEREDOAK30
42"
30"
18"
24"
ASHTONWHITEBIRCH36
OZARKCHARREDOAK36
SMOKYWEATHEREDOAK36
48"
36"
18"
24"