background image

D U S T   B I N   O V E R V I E W

4

Filter mesh bracket

Primary Filter 
Filter Mesh

Charging contacts

Dust collection port

Mop pad

Bin release button 

Dust collection port 

Water fill cap

Dust bin latch

Mop attachment

HEPA Filter

Summary of Contents for Nova iHRV6

Page 1: ...Owner s Guide Model iHRV6 ...

Page 2: ... Troubleshooting 19 20 FCC Info 21 Questions Contact Customer Service Web iHomeautovac com Email Support silverpointtech com Phone 877 370 4580 Check out our helpful setup videos For support content and the latest digital version of this manual scan the QR code below or visit ihomeautovac com novavideos ...

Page 3: ... wool hair etc to ensure smooth air circulation at the suction port Use the power cord carefully to avoid damage Do not use the power cord to drag or pull the product and the charging base Do not use the power cord as a handle Only authorized technicians can disassemble this product Users are not recommended to disassemble this product by themselves Doing so will void warranty Only use the include...

Page 4: ... Empty Base 1 3 Power Cable 1 4 2 in 1 Dustbin Mop Tank 1 5 Powermop attachment 1 6 Remote Control 1 7 Dust Bag 2 8 User Manual 1 9 Mop Pad 2 10 HEPA Filter 2 11 Side Brush 2 12 Brush Cleaning Tool 1 No Description Quantity 1 2 3 4 5 6 7 8 9 10 11 12 ...

Page 5: ...rared sensors Charging contacts Bin release button Dust collection port 2 in 1 Dustbin Mop tank Infrared auxiliary recharge sensor Omnidirectional wheel Cliff detect sensor Right wheel Side brush Left wheel Rolling brush 2 in 1 Dustbin Mop tank FRONT REAR BOTTOM ...

Page 6: ... BIN OVERVIEW 4 Filter mesh bracket Primary Filter Filter Mesh Charging contacts Dust collection port Mop pad Bin release button Dust collection port Water fill cap Dust bin latch Mop attachment HEPA Filter ...

Page 7: ...an filter Dust collection duct cover Air outlet Power interface Dust bag handle Dust bag TOP FRONT BOTTOM REAR NOTE 1 One dustbag already pre installed in Auto Empty Base 2 Dustbag may appear deflated This is normal 3 Dustbag handle must be fully lowered as shown in order for debris to enter properly ...

Page 8: ...tion Press hold at the same time for 5 seconds to enter network configuration Flashing blue light Powering on configuring network upgrading firmware Solid blue light Powered on normal working state Flashing yellow light Low battery recharging Flashing green light Charging Solid green light Fully charged Flashing red light Error state Light off Off sleeping Reset Forced shutdown button ...

Page 9: ... red light Fan overheating fan error cover not closed Power Indicator Flashing green light Charging Solid green light Fully charged standby Dust Bag Indicator Solid green light Dust bag is full dust duct is blocked Flashing red light Dust bag is not installed dust bag is not installed correctly ...

Page 10: ...all outlet Place on a flat hard surface at least 2 5 inches away from the wall Ensure that there is a clear space in front and both sides so that your Autovac Nova can return to Base to re charge and empty 2 5 inches from the wall How to place your Auto Empty Base NOTE The Auto Empty Base must always remain connected to power Avoid using a power source that may inadvertent ly be switched off e g po...

Page 11: ... Voice prompt volume can be adjusted later in the iHome Clean App or muted using the remote control Step 2 Press the Home button to pair Nova to your Auto Empty Base Nova will navigate and dock to the base Allow Nova to fully charge before first use NOTE Dust collection may activate during initial docking Do not be alarmed Dust collection frequency can be adjusted later in the iHome Clean App ...

Page 12: ...y changes moved furniture or other obstructions into account Once cleaning is finished or the battery is low the Nova will automatically return to the Auto Empty Base to charge and automatically empty the contents of the dustbin NOTE Connecting Nova to Wi Fi is not required but highly recommended Using the iHome Clean app you can follow the steps below to connect your Nova The app will let you mana...

Page 13: ... WI FI CONNECTION 11 5 Go to Wi Fi settings on your device and select Autovac Nova 6 Re open the iHome Clean App wait for the connection to complete 2 Open the iHome Clean App select Add device and select Nova 4 Select your 2 4G Wi Fi network and enter the password 3 Press hold simultaneously for 5 seconds to enter network config mode NOTE Ensure that you have a strong Wi Fi signal in the location ...

Page 14: ...y the dustbin If a cleaning session was interrupted due to low battery Nova will automatically resume cleaning once the power has been sufficiently restored Cleaning Modes Auto Clean The Nova will automatically clean your floor until it has covered the entire surface Once cleaning is finished or the battery needs to be re charged the Nova will automatically return back to the Auto Empty Base to empty...

Page 15: ...ed to point the remote to the front of the Nova for best results 2 The remote control range is 10 20 feet Home Button Powermop Spot Cleaning Decrease Suction Power Manual Navigation Directional Keys Start Pause Button Mute Increase Suction Power Hyperdrive Mode ...

Page 16: ... on the dustbin and fill with water then close cap 2 Slide mop attachment onto dustbin as shown in the figure below until you hear a click confirming that it is locked in place Your Autovac Nova comes equipped with a 2 in 1 Dustbin and water tank All Nova cleaning modes activate dry vacuuming by default The wet mopping feature adds an additional cleaning element whenever necessary Follow these steps ...

Page 17: ... performance 1 Pinch the left and right tabs on the main brush cover Lift and remove the cover 2 Remove the main brush and clean with included cleaning tool as seen in the figure below 3 Replace the main brush and snap the cover back into place NOTE It is recommended to replace the main brush every 6 12 months depending on use Main Brush Once a month Once a year Once a month Once a year Every 2 wee...

Page 18: ... contents 4 Remove the mop pad to wash machine washable 1 Press the dust bin release button and remove the dust bin 3 Remove the primary filter and HEPA filter wipe down the surface with a dry cloth or use the cleaning tool Rinse the primary filter with water and let dry ...

Page 19: ...Use a Philips screwdriver to unscrew the side brush screw and remove the side brush 2 Remove dirt and debris and reinstall using Philips screwdriver NOTE It is recommended to replace the side brush every 3 6 months depending on use ...

Page 20: ...om handle Discard the old dust bag Replace with new dust bag fully lower cardboard handle Close cover flashes or the is solid green and the dust bag Filter Maintenance If the Auto Empty Base indicator light is not full it is time to clean the filter 1 Unplug the Auto Empty Base and turn it over Use a Philips screwdriver to remove the screws as shown in the figure to the right Open the dust duct cover...

Page 21: ...or after moving it far from the Auto Empty Base After spot cleaning or moving the Nova far from the Auto Empty Base the Nova will re generate the map If the Nova is far from the Auto Empty Base it may not be able to locate it Please manually dock the Nova to the Auto Empty Base to recharge Abnormal noise during cleaning Main brush side brush or left right wheel may be obstruction Check underneath ...

Page 22: ...matter INDICATOR DEFINITION SOLUTION The dust bag is not installed The dust bag not installed properly The Auto Empty Base cover is open 1 Replace with a new dust bag 2 Check whether the dust bag is installed if not please install the dust bag 3 Check if the dust bag is installed correctly and in place 4 Make sure that the Auto Empty Base cover is completely closed and sealed and that the Nova is ...

Page 23: ... if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the in...