2 INSTRUCTIONS
FOR
USE
MINIDUMPER
CARRY 107
17
2.7.12 INSTALLING THE HI FLOW AUXILIARY PTO. (OPTIONAL ACCESSORY)
Remove the front housing on the bin side, and unscrew the oil filler cap to depressurise the hydraulic circuit (ref. chapter
3.7)
Mount fittings 3 and 4 to the hydraulic junction 1. Fit the hydraulic junction to its mounting point with the bracket 2 and the
provided bolts, washers and nuts. Disconnect hoses A and B from the manifold and connect them to the hydraulic
junction. Connect hoses 5 and 6 from the hydraulic junction to the manifold. Make sure the hoses are securely installed.
Repressurise the hydraulic circuit (ref. chapter 3.7). For information on operating the “Hi-flow PTO”, refer to § 2.7.6.