Remember to: 

1. Make sure that the appropriate cuff size is used; refer to the cuff circumference range in the Specifications section 

of this manual. 

2. Measure on the same arm each time. 

3. Stay still during measurement. Do not move your arm, body or the monitor. 

4. Stay still and calm for one to one and half minutes before taking a blood pressure measurement. Prolonged 

over-inflation of the bladder may cause ecchymoma of your arm. 

5. Keep the cuff clean. Cleaning the cuff after every 200 times of usage is recommended. If the cuff becomes dirty, 

clean it with a moistened cloth. Do not rinse the monitor or cuff with running water.   

 

     Left arm measurement                        Right arm measurement 

 

TAKING YOUR BLOOD PRESSURE READING 

The iHealth CardioMed Ambulatory Blood Pressure Monitor has two measurement modes. Preparing your patient for 

the ABPM study is the most important step to achieving a successful test. 

TAKING YOUR BLOOD PRESSURE READING MANUALLY 

 

a. 

Long press the 

  button, the monitor will activate and all display characters 

are shown for self-test. You can check the LED screen display according to the right 

picture. Please contact the service center if symbol is missing. 

 

 

b. Then the cuff will be slowly inflated. The blood pressure and pulse will be measured 

during inflation. Inflation will stop as soon as the blood pressure and pulse rate have been 

calculated and displayed on the screen. The result will be automatically stored in the 

memory, and all results will be uploaded to the App automatically upon the next successful 

Bluetooth connection. 

 

 

b. 

During measurement, you can press the 

 button or 

  button to turn off 

the monitor manually. 

c. 

After measurement, the monitor will display SYS and DIA in first screen, and 

then display pulse rate in 2 seconds or press any button, and turn off display in 2 

seconds or press any button.

 

Note: Manual test readings taken before automatic mode is configured cannot be stored in memory.

 

Summary of Contents for ABP100

Page 1: ...NTS 6 BATTERY HANDLING AND USAGE 6 SET UP PROCEDURES 7 ABPM SYNC AND SETUP 7 MEASUREMENT PROCEDURES 8 TAKING YOUR BLOOD PRESSURE READING 9 TAKING YOUR BLOOD PRESSURE READING MANUALLY 9 TAKING YOUR BLO...

Page 2: ...hypertension z Assessment of treatment Assessing 24 h BP control Identifying true resistant hypertension z Assessing morning hypertension and morning BP surge z Screening and follow up of obstructive...

Page 3: ...ce of adjacent pulse period is 0 14s and more than 53 percent of the total number of pulses readings falls within this definition z This product should not be used as a USB device z If the blood press...

Page 4: ...IBILITY INFORMATION It is suggested that the blood pressure monitor be kept 10 meters away from other wireless devices such as WLAN unit microwave oven etc z The results of blood pressure measurements...

Page 5: ...l of the cuff Please consult a physician for specific situation z It is recommended that the patient record important events such as take medicine taking time drug name drug dose etc awake and asleep...

Page 6: ...asurements on a full charge 19 The blood pressure measurement system includes accessories pump valve cuff LED screen and sensor Note These specifications are subject to change without notice SET UP RE...

Page 7: ...Health service provider Battery life and charge cycles vary by use and settings SET UP PROCEDURES Download the Free iHealth App Prior to first use scan QR code and download the iHealth App Follow the...

Page 8: ...surement Lying Down During Measurement a Lie on your back b Place your arm straight along your side with your hand palm side up c The cuff should be placed at the same level as your heart Note Blood p...

Page 9: ...tep to achieving a successful test TAKING YOUR BLOOD PRESSURE READING MANUALLY a Long press the button the monitor will activate and all display characters are shown for self test You can check the LE...

Page 10: ...d When Auto Mode on the monitor will continue take measurements in the scheduled time and after the monitor get enough readings the monitor automatic stop taking readings Note Please consult a health...

Page 11: ...g the button and holding for about 10 seconds then connect the mobile device correctly and try again If the monitor is still abnormal please contact the local distributor or the factory LED display re...

Page 12: ...2 years or after each repair Please contact the customer service z Do not use the device if you think it is damaged or if anything appears unusual Please refer your device to qualified service personn...

Page 13: ...Paris France support ihealthlabs eu www ihealthlabs eu ANDON HEALTH CO LTD No 3 Jinping Street YaAn Road Nankai District Tianjin 300190 China Tel 86 22 60526161 IMPORTANT INFORMATION REQUIRED BY THE...

Page 14: ...pe and its gain should be so chosen that the equivalent isotropically radiated power e i r p is not more than that necessary for successful communication Conform ment la r glementation d Industrie Can...

Page 15: ...n IEC 61000 3 2 Class A Home healthcare environment Voltage fluctuations and flicker IEC 61000 3 3 Compliance Home healthcare environment Table 2 Enclosure Port Phenomenon Basic EMC standard Immunity...

Page 16: ...4 2 kV 100kHz repetition frequency Surges Line to line IEC 61000 4 5 0 5 kV 1 kV Surges Line to ground IEC 61000 4 5 0 5 kV 1 kV 2 kV Conducted disturbances induced by RF fields IEC 61000 4 6 3V 0 15...

Reviews: