Use of pressure gauge on top of cylinder: 

 

This pressure gauge needs to show an 
operating pressure of 0.7 for the unit 
to be creating microbubbles at the 
highest efficiency.   
 
In start-up operation the pressure will 
read anywhere either side of 0.7.  An 
operator needs to adjust the air flow 
to achieve a 0.7 reading on this 
gauge.  No other action is required 
for this cylinder or gauge except to 
check the pressure now and then. 
 

Note:

  to adjust the pressure you need to adjust the air intake actuator. 

 

Adjusting the air intake actuator: 

 

The air intake actuator is the right-hand side 
actuator which has the blue open plug injected 
in the right-hand side of the pipe above the 
actuator.   
 
To adjust the pressure in the cylinder, open 
the red handle tap that can be seen behind the 
wiring at the front of the actuator.  Open this 
tap fully by pushing it toward the bottom of 
the unit until it is in a vertical position. 
 
Next turn the set screw at the top of the pipe 
shown here and adjust by raising or lowering 
the screw until the pressure on the gauge is 
showing 0.7.   
 

Summary of Contents for MBG-N5.5

Page 1: ...OPERATION AND MAINTENANCE MANUAL Version 2 April 2019...

Page 2: ...assist in control of unit for bubble generation Suction hose that connects foot valve to inlet Suction Hose that connects foot valve to primer pump Foot valve in cage High pressure delivery hose with...

Page 3: ...uccessfully operate outside in all weathers The product requires mechanical lifting equipment to place into position or shift from one position to another It is feasible to bolt the frame to a specifi...

Page 4: ...for tightness If unit continues to leak then shut down and remove the delivery hose and check for damage to the seal If seal is damaged replace seal and reconnect How to connect to the water source T...

Page 5: ...other end of the larger hose is connected to the fitting found on the lower left side of the unit and inside the unit Feed the hose though the hole provided This connection is in front of the dischar...

Page 6: ...length is required if the unit is relocated this can be achieved using a three phase extension making sure that any connection is kept out of water that may be around the unit Connection is simple and...

Page 7: ...purpose one is to prime the main pump at start up and the other is to prime the main pump during operation as required This process is automated and requires no operator intervention once the switch i...

Page 8: ...and has a set screw adjustment on the top There is no need to adjust the left hand actuator Take care as this actuator does get hot You will not need to adjust the right hand actuator only the air val...

Page 9: ...e to adjust the pressure you need to adjust the air intake actuator Adjusting the air intake actuator The air intake actuator is the right hand side actuator which has the blue open plug injected in t...

Page 10: ...bles will clear once the unit is turned off as they break to nanobubbles and both remain in the water as a bank of air for some considerable time Maintenance The Microbubble Generator is designed to o...

Page 11: ...ure the unit is creating microbubbles at its optimum capacity If it is noticed this tends to change check the lock nut has not worked loose If it has readjust and retighten the lock nut Also check the...

Reviews: