Have the orange valve fully open: 

 

If this valve is included in your unit, ensure 
it is fully open during operation.  This 
ensures the valve does not throttle the water 
flow in any way.  The photo at left shows 
the valve partially closed – make sure this 
remains fully open during operation. 

 

 

Connection of electrical power lead: 

 

The orange power lead shown at left at the bottom 
of the electrical board needs to be connected by an 
authorised electrician and has enough length to 
allow you to connect to a three-phase electricity 
supply. 
 
If additional length is required if the unit is relocated 
this can be achieved using a three-phase extension, 
making sure that any connection is kept out of water 
that may be around the unit. 
Connection is simple and if in doubt seek the advice 
of an electrician. 
 

Once the above connections are made with the unit in a stable upright position 
you will be ready to turn the unit on and commence the production of 
microbubbles, which will in turn break down to nanobubbles.   Double check all 
connections at this point. 
 
Lower the foot valve with the two hoses connected into the water source.   
Make sure that the cage is suspended in such a way it can operate without 
obstruction or is sitting comfortably on the base of the water source if a tank. 

 

 
 
 

To start the MBG: 

Summary of Contents for MBG-N5.5

Page 1: ...OPERATION AND MAINTENANCE MANUAL Version 2 April 2019...

Page 2: ...assist in control of unit for bubble generation Suction hose that connects foot valve to inlet Suction Hose that connects foot valve to primer pump Foot valve in cage High pressure delivery hose with...

Page 3: ...uccessfully operate outside in all weathers The product requires mechanical lifting equipment to place into position or shift from one position to another It is feasible to bolt the frame to a specifi...

Page 4: ...for tightness If unit continues to leak then shut down and remove the delivery hose and check for damage to the seal If seal is damaged replace seal and reconnect How to connect to the water source T...

Page 5: ...other end of the larger hose is connected to the fitting found on the lower left side of the unit and inside the unit Feed the hose though the hole provided This connection is in front of the dischar...

Page 6: ...length is required if the unit is relocated this can be achieved using a three phase extension making sure that any connection is kept out of water that may be around the unit Connection is simple and...

Page 7: ...purpose one is to prime the main pump at start up and the other is to prime the main pump during operation as required This process is automated and requires no operator intervention once the switch i...

Page 8: ...and has a set screw adjustment on the top There is no need to adjust the left hand actuator Take care as this actuator does get hot You will not need to adjust the right hand actuator only the air val...

Page 9: ...e to adjust the pressure you need to adjust the air intake actuator Adjusting the air intake actuator The air intake actuator is the right hand side actuator which has the blue open plug injected in t...

Page 10: ...bles will clear once the unit is turned off as they break to nanobubbles and both remain in the water as a bank of air for some considerable time Maintenance The Microbubble Generator is designed to o...

Page 11: ...ure the unit is creating microbubbles at its optimum capacity If it is noticed this tends to change check the lock nut has not worked loose If it has readjust and retighten the lock nut Also check the...

Reviews: