Should it stop operating check the water supply is still OK and start again. If the
pump still does not work the electrical supply will need to be checked. If the
electrical supply is found OK, then contact IGS for further assistance.
Actuators:
These actuators are critical for the
operation of the system. The actuator on
the right has a tap below it (behind the
wiring), which brings air in from the side
(blue open plug) and has a set screw
adjustment on the top.
There is no need to adjust the left-hand
actuator. Take care as this actuator does
get hot. You will not need to adjust the
right-hand actuator, only the air valve.
Cavitation cylinder:
The cavitation cylinder is a critical operational
component of the product for the creation of
microbubbles. It is found at the rear of the unit on
the left-hand side, under the electrical enclosure.
On the top of this cylinder is a pressure gauge
which will need to be checked in operation, with
adjustments made on the air intake actuator.
No other operator input is required for this cylinder.