Shown at left is the foot valve connected and 
lying on the bottom of a tank. 
 
At the top of the picture, you can see there are 
two clear hoses connected to the foot valve.  
Connect these two hoses to the foot valve with 
the larger hose connected to the applicable 
piping and the smaller hose connected to the 
smaller pipe. 
 
Secure both hoses with the supplied clamps 
and tighten to a normal tightness for this type 
of fitting.  There is no need to overtighten 
either of these connections. 
 
The other end of the larger hose is connected 
to the fitting found on the lower left side of 
the unit and inside the unit.  Feed the hose 
though the hole provided.   This connection is 
in front of the discharge connection and is 
easy to recognise as it is a push on fitting and 
not screwed on. 
 
As with the foot valve, use the supplied clamp 
to tighten the connection.  Normal tightness is 
sufficient and there is no need to overtighten. 
 
The smaller suction hose is connected to the 
primer pump as shown here.  Feed this hose 
through the hole provided on the left-hand 
side of the unit and connect as shown in the 
photo to the left.  
 
As with the other clamps tighten as needed 
without over-tightening. 

 

 

Summary of Contents for MBG-N5.5

Page 1: ...OPERATION AND MAINTENANCE MANUAL Version 2 April 2019...

Page 2: ...assist in control of unit for bubble generation Suction hose that connects foot valve to inlet Suction Hose that connects foot valve to primer pump Foot valve in cage High pressure delivery hose with...

Page 3: ...uccessfully operate outside in all weathers The product requires mechanical lifting equipment to place into position or shift from one position to another It is feasible to bolt the frame to a specifi...

Page 4: ...for tightness If unit continues to leak then shut down and remove the delivery hose and check for damage to the seal If seal is damaged replace seal and reconnect How to connect to the water source T...

Page 5: ...other end of the larger hose is connected to the fitting found on the lower left side of the unit and inside the unit Feed the hose though the hole provided This connection is in front of the dischar...

Page 6: ...length is required if the unit is relocated this can be achieved using a three phase extension making sure that any connection is kept out of water that may be around the unit Connection is simple and...

Page 7: ...purpose one is to prime the main pump at start up and the other is to prime the main pump during operation as required This process is automated and requires no operator intervention once the switch i...

Page 8: ...and has a set screw adjustment on the top There is no need to adjust the left hand actuator Take care as this actuator does get hot You will not need to adjust the right hand actuator only the air val...

Page 9: ...e to adjust the pressure you need to adjust the air intake actuator Adjusting the air intake actuator The air intake actuator is the right hand side actuator which has the blue open plug injected in t...

Page 10: ...bles will clear once the unit is turned off as they break to nanobubbles and both remain in the water as a bank of air for some considerable time Maintenance The Microbubble Generator is designed to o...

Page 11: ...ure the unit is creating microbubbles at its optimum capacity If it is noticed this tends to change check the lock nut has not worked loose If it has readjust and retighten the lock nut Also check the...

Reviews: