19
4.5.
Chimney Instructions
The main cause of the chimney fire;
Improper selection or pipe that dust is flammable fuel.
In the event of appropriate conditions can cause fires ignite in the ducts.
Ways of avoiding them;
The chimney should be cleaned at least 2 times per year, depending on the
fuel quality.
Correct and appropriate chimney selection should be made.
Ensuring that the sealing and smoke in the chimney pipe and must be made
in isolation.
After installation, chimney cleaning must be done before ignition operation.
In case of a re-ignition after prolonged period of time, the smoke paths and
flue congestion must be checked.
Surrounding the peak point of the roof of the chimney to the interference of
the obstacle (the ridge) from height must be at least 80 cm.
Stove is not suitable for a shared chimney system.
There should be no cracks on the flue to prevent the flue gas from leaking.
The inner surface of the chimney should be smooth.
Should chimney's pipe inner diameter is 130 mm. (For star 150mm)
Chimney flue test should be performed before making connections. If the
chimney connections should be carried out after removal of the traction
problem had this problem in the chimney.
The stove pipe connected to the horizontal flue pipe must not be longer than
2m. It is recommended to use 45
⁰
elbows in chimney pipes instead of 90
⁰
bend. (Site selection for stoves should be determined by the closest point
where the chimney.)
To avoid turbulence around the chimney flue without any obstructions (high
buildings, trees, etc.) Must be at least 10 m away.