18
4.3.3. Plumbing Water Specification
Properties that should be in boiler water; EN 12953-10 “Shell boilers- Part 10:
Requirements for feedwater and boiler water quality” must comply with the
standard. In the boiler and heating system, water in quality of drink water
should be used in order to prevent damage caused by corrosion. Aggressive
water should not be used for chemical additives because of corrosion. The
water content to be filled in the boiler and the installation must not contain
residues, dirt and undesirable solid particles. These deposits and dirt are
extremely harmful to the circulation pump. If you are suspected that the water
is not clean, necessary precautions should be taken.
Calcified water used in the system forms a lime and mud layer on the heating
surfaces of the boiler. This lime and mud layer prevents water circulation and
heat transfer and deforms the boiler.
This is not covered by the warranty.
4.4.
Ventilation And Air Flow
In the room where the stove is installed, there should be enough air to allow
regular combustion.
The location of stove fresh air inlet must be provided.
It is recommended that the stove should be connected to an environment
(external environment) where the air suction pipe can be continuously
flowing clean air with hermetic pipe.
Use 300 cm² lower, 200 cm² upper orifice. These grilles should never be
closed. Otherwise, it presents a great danger.
Avoid installing the unit in the same environment with the following;
o
B type gas heaters or exhaust fan or fan less hoods
o
Collective ventilation pipes.
o
Aspirator device running in the same environment, can cause problems.