27
7. USED HARDWARES OF STOVE
7.1.
Thermostat Use And Specifications
Thermostat specification;
Tolerance :
%
±1
Operating Interval :
°C
0-120
Storage Temperature Range :
°C
(-40) - (125)
Long-term deviation :
°C / year
<0.04
Dimensions :
mm
65x33x74
Thermostat to adjust the operating temperature in the stove;
First cut off electricity.
Turn the power cord back on while the thermostat adjustment button is
pressed.
You can set the flashing temperature value on the thermostat display by
pressing the button.
Remember that the value you set is the temperature at which the pump
starts operating.
This setting is not for adjusting the water temperature in the stove.
The circulation pump is for operating temperature setting.
If you see "err" on thermostat screen;
The temperature probe indicates that the probe is faulty or has a fault in the
cable connection.
If there is a '' err '' error on the screen, the pump will run continuously. This
situation was created for the safety of your stove.
In the event that the temperature error in the temperature probe is
removed, the error is cleared and the thermostat normally continues to
operate at the set temperature.