9
Factory setting of the Ethernet parameters
The following values are preset on delivery of the device:
Parameters
Factory setting
IP address
192 .168 .0 .79
Gateway address
192 .168 .0 .100
Subnet mask
255 .255 .255 .0
Auto-negotiation
on
DHCP
off
The settings can be changed via the web server of the device or via the Ethernet host.
Reset to factory settings
The Ethernet parameters and the password of the device can be reset to the factory settings. Take the
following steps:
►
Remove all cable connections from the device.
►
Insert an electrically conductive bridge between pin 2 and pin 4 on the process connection voltage supply
PWR.
►
Connect the unit to the voltage supply.
The LEDs of the signal bar (yellow) are on one after the other. Then LED 4 of the signal bar (yellow)
flashes at 8 Hz.
►
As soon as the LEDs of the signal bar (yellow) flash at 8 Hz, disconnect the unit
►
Remove the bridge.
►
Connect the device to the voltage.
►
The settings are reset.