Example of URL for ANT513 connected at IO port 1 at DTE105 :
http://192.168.0.79/rwhupdate?ioport=1&anttype=ANT600&fwVersion=1&setLng=en
Example of URL for DTE605 :
http://192.168.0.79/rwhupdate?ioport=1&anttype=DTE60X&fwVersion=1&setLng=en
Example of URL for DTE805 :
http://192.168.0.79/rwhupdate?ioport=1&anttype=DTE80X&fwVersion=1&setLng=en
Example of URL for DTE905 :
http://192.168.0.79/rwhupdate?ioport=1&anttype=DTE90X&fwVersion=1&setLng=en
After finishing the firmware update of the Read-/Write head, enter the URL of the device to return to
the main menu
Tab "IO-Port"
This menu allows to configure the Read-/Write head and the IO-Ports of the device.
Read-/Write head
The user data length of the read / write head cannot be configured. The maximum length can be up to 1024
characters.
Parameter “Data hold time” define how long the RFID data are kept stable. This is helpful if the time interval, in
which the ID tag data are available, is shorter than the Ethernet host can read these over the fieldbus.