CompactModul Metall CR2032
12
Parameter
Index in ob-
ject directory
Default
(factory preset)
Change automati-
cally saved
Change
effective
Event Timer Trans PDO1 1800 05
0x00
adjustable
immediately
COB ID Trans PDO 2
1801 01
0x280 + Node ID
adjustable
after a reset
Trans Type Trans PDO 2
1801 02
0x01 (synchronous) adjustable
immediately
Event Timer Trans PDO2 1801 05
0x00
adjustable
immediately
The life time factor 0 is interpreted as 1�
The first guard protocol is assessed as "start guarding" even if guarding is not active at this time (guard time =
0)�
*) Observe the position of the hex-code switch!
Entries in the object directory are only valid if the hex-code switches for baud rate (S1) and/or node ID (S2,
S3) are in the position "F"�
(For position and coding of the hex-code switches see connecting and operating elements
)
Explanation of the abbreviations:
0x��� = hexadecimal value
0b��� = bit coded
0d��� = decimal numerical value
str = string
rw = read-write
ro = read only
u8 = unsigned 8 bit
u16 = unsigned 16 bit