IO-Link Master with Modbus TCP Interface DataLine 4 Ports IP 65 / IP 66 / IP 67
109
0
Port No.
1
reserved
2
reserved
3
0x30
User ID
4
Result
5
Data Length (Number of Bytes)
6
reserved / Error Code
Failsafe Mode / Additional Code
7 ... 21
reserved
Legend:
[Port No.]
Number of the IO-Link port
1 Word
0x0001
Port X01
0x0002
Port X02
...
...
0x0004
Port X04
[User ID]
reflected User ID from request channel
1 byte
0x00...0xFF
[Result]
Status of the command processing
1 Word
0x0000
OK
0x00FF
Error
[Data Length
(Number of
Bytes)]
Number of bytes that contain relevant user data
1 word
0x0001
1 byte
0x0002
2 bytes
[Failsafe Mode]
Fail-safe mode for the outputs of the IO-Link ports
in case of an interruption of the Modbus TCP
connection
1 byte
0x00
No Failsafe
0x01
Failsafe: Reset Value
0x02
Failsafe: Old Value
0x03
Failsafe: with Pattern
[Error Code]
Error ID
1 byte
→
Error codes
(
→ S.
[Additional Code]
additional error codes
1 byte
→
Additional Codes
(
→ S.