IO-Link Master with Modbus TCP Interface DataLine 4 Ports IP 65 / IP 66 / IP 67
107
>
Command response
34497
Register
Contents
Bits 8-15
Bits 0-7
0
Port No.
1
reserved
2
reserved
3
0x10
User ID
4
Result
5
Data Length (Number of Bytes)
6
reserved / Error Code
Validation ID / Additional Code
7 ... 21
reserved
Legend:
[Port No.]
Number of the IO-Link port
1 word
0x0001
Port X01
0x0002
Port X02
...
...
0x0004
Port X04
[User ID]
reflected user ID from request channel
1 byte
0x00 .. 0xFF
[Result]
Status of the command processing
1 byte
0x00
OK
0xFF
Error
[Data Length
(Number of
Bytes)]
Number of bytes that contain relevant user data
1 word
0x0001
1 byte
0x0002
2 bytes
[Validation ID]
Supported IO-Link standard and behaviour of the
IO-Link master when connecting new IO-Link
devices to the IO-Link port
1 byte
0x00
no validation
0x01
V1.0 device
0x02
V1.1 device
0x03
V1.1 device, restore
0x04
V1.1 device, backup
[Error Code]
Error ID
1 byte
→
Error codes
(
→ S.
[Additional
Code]
additional error codes
1 byte
→
Additional Codes
(
→ S.
>