6 - USE AND OPERATION
Boss 338HD - 552HD
EN
6 - Pag. 17 / 17
6.5.2 Lubrication oil - Flow adjustment
The oil flow in the guide channels and bush holder
device is automatically controlled during the bar
feeder automatic cycle.
The pump is started when the bar feeder has
completed the bar change and stops when the bar
pusher approaches the bush holder device.
Oil flow should be adjusted according to bar
diameter and profile through the valve placed
upstream.
• Adjust oil flow in the bush holder device as
well.