7 - BAR FEEDER MAINTENANCE
Boss 338HD - 552HD
EN
7 - Pag. 5 / 5
7.2.3 Lubricating oil - Change
WARNING - CAUTION:
wear personal protections according to the regulations in force.
INFORMATION:
store drain oil in special containers to be delivered to companies specialised in
pollutant disposal and storage.
Avoid environmental pollution.
• Drain the tank using an auxiliary pump. Clean the tank bottom and the pump suction system.
• For the loading, pour the oil directly in the tank and check the level through the indicator
"A".
See the "TECHNICAL DATA" section, Chap. 2, for the comparison table.