iSignager-1000-Q354 Digital Signage Player
Page 164
F.1 Introduction
The Intel
®
ICH9DO chipset can provide data protection for serial ATA (SATA) disks via the
Intel
®
Matrix Storage Manager using one of three fault-tolerant RAID levels: RAID 1, 5 or
10. When using two hard drives, matrix RAID allows RAID 0 and RAID 1 functions to be
combined, where critical files can be stored on RAID 1, and RAID 0 can be used for
non-critical items such as software. RAID 5 and RAID 0 can be combined to provide
higher performance, capacity, and fault tolerance.
CAUTION!
A configured RAID volume (which may consist of multiple hard drives) appears
to an operating system as a contingent storage space. The operating system
will not be able to distinguish the physical disk drives contained in a RAID
configuration.
F.1.1 Precautions
One key benefit a RAID configuration brings is that a single hard drive can fail within a
RAID array without damaging data. With RAID1 array, a failed drive can be replaced and
the RAID configuration restored.
WARNING!
Irrecoverable data loss occurs if a working drive is removed when trying to
remove a failed drive. It is strongly recommended to mark the physical
connections of all SATA disk drives. Drive locations can be identified by
attaching stickers to the drive bays. If a drive member of a RAID array should
fail, the failed drive can then be correctly identified.
CAUTION!
Summary of Contents for iSignager-1000-Q354
Page 14: ......
Page 15: ...iSignager 1000 Q354 Digital Signage Player Page 1 1 Introduction Chapter 1 ...
Page 21: ...iSignager 1000 Q354 Digital Signage Player Page 7 2 Mechanical Description Chapter 2 ...
Page 27: ...iSignager 1000 Q354 Digital Signage Player Page 13 Figure 2 4 Internal Overview ...
Page 28: ...iSignager 1000 Q354 Digital Signage Player Page 14 3 System Components Chapter 3 ...
Page 40: ...iSignager 1000 Q354 Digital Signage Player Page 26 4 Installation Chapter 4 ...
Page 45: ...iSignager 1000 Q354 Digital Signage Player Page 31 Figure 4 2 Power Button and Power LED ...
Page 46: ...iSignager 1000 Q354 Digital Signage Player Page 32 5 AMI BIOS Chapter 5 ...
Page 91: ...iSignager 1000 Q354 Digital Signage Player Page 77 6 Driver Installation Chapter 6 ...
Page 117: ...iSignager 1000 Q354 Digital Signage Player Page 103 7 Software Application iSMM Chapter 7 ...
Page 133: ...iSignager 1000 Q354 Digital Signage Player Page 119 Figure 7 19 Load Save Page ...
Page 154: ...iSignager 1000 Q354 Digital Signage Player Page 140 A Safety Precautions Appendix A ...
Page 158: ...iSignager 1000 Q354 Digital Signage Player Page 144 ...
Page 159: ...iSignager 1000 Q354 Digital Signage Player Page 145 B Interface Connectors Appendix B ...
Page 166: ...iSignager 1000 Q354 Digital Signage Player Page 152 C BIOS Menu Options Appendix C ...
Page 170: ...iSignager 1000 Q354 Digital Signage Player Page 156 D Watchdog Timer Appendix D ...
Page 177: ...iSignager 1000 Q354 Digital Signage Player Page 163 F Intel Matrix Storage Manager Appendix F ...