background image

Testing the alarm:

Check once a week that the alarm is working properly by briefly pressing down the 

Test/

Mute button (picture 5b)

. The alarm will beep 2 or more times and the 3 LEDs 

(picture 5c)

 

will light up briefly. Afterwards the alarm returns to its normal operating mode.

Cleaning the alarm:

Loose dust inside the alarm can be sucked out through the vents using a vacuum cleaner.

The alarm cover can be cleaned from the outside with a lightly dampened cloth. Under no

circumstances use any domestic cleaners containing ammonia or any other chemicals

(such as cleaning agents or solvents) on or anywhere near the alarm. Do not get paint or

varnish on the alarm!

Battery and rechargeable battery information

Old batteries may not be disposed of with the unsorted househol waste Owners of used 

batteries are legally obliged to recycle the batteries and can return them free of charge 

to the place of sale. Batteries contain  material which is harmful to the environment and 

health, and must therefore be disposed of professionally.

Recycling instructions

This device must not be disposed of with unsorted household waste. Owners of old 

devices are required by law to dispose of this device correctly. Contact your town council 

for further information.

7.  Technical data

Battery operated 

3 x 1.5 V alkaline (AA/Mignon)

Calibrated acc. to 

EN 50291

Alarm volume 

approx. 85 dB/3 m

Permissible ambient temperature 

+4 °C... +38 °C

Permissible humidity 

10 %... 95 % non-condensing

Size  

Ø 125 mm, height 33 mm

Life 

approx. 5 years

8

CO concentration in air 

No. minutes before alarm triggered

50 ppm 

60 - 90

100 ppm 

10 - 40 

300 ppm 

Trigger level in accordance with EN 50291:

Subject to technical and design changes without prior notice.

Table of functions:

Sound 

Green Power LED  Red Alarm LED 

Yellow Fault LED  Meaning

none 

flashes every 60 s 

off 

off 

working normally

beeps every 60 secs  

off 

off 

flashes every  

battery low, see 6. Maintenance 

 

 

 

60 secs

beeps every 60 secs 

off 

off 

constantly lit 

alarm is not locked into  

 

 

 

 

mounting plate

beeps every 2 secs 

flashes every 2 s 

flashes every 2 s 

flashes every 2 s 

test function

beeps every 60 secs 

off 

off 

flashes 3 x  

device faulty, replace 

 

 

 

every 60 s 

immediately

beeps every 60 secs 

flashes every 60 s 

flashes 

off 

muted

intermittent alarm 

off 

flashes 

off 

alarm triggered, see section 3

6. Maintenance

Changing the battery:

The batteries should be changed at least once a year or immediately if the low battery alert 

sounds. When changing the batteries, the alarm must 

not

 be dismounted.

1. Open the battery compartment by pressing the release 

(picture 5a)

 while at the same time  

  sliding the compartment cover downwards 

(picture 5b)

. Do not dispose of the batteries with  

  your household waste. The end user must recycle all used batteries. Batteries may be 

  returned free-of-charge to the place of sale or to your local collection point.

2. Insert 3 new batteries 

the right way round (picture 6)

 and make sure that the red pins are 

  in contact with each battery. The alarm confirms that the batteries are in place with a short  

 beep.

3. Close the battery compartment by placing the cover on the alarm and sliding it upwards 

  until it click in.

4. Test the alarm straightaway 

(see Operating test)

.

We recommend the following 1.5 V alkaline batteries, size AA/Mignon:

Duracell MN 1500, Energizer E91
Under normal conditions new batteries will last for around a year – depending on the number 

of tests. If the alarm is subjected for prolonged periods to high or low temperatures, or to 

high air humidity, then the batteries’ useful life will become shorter.

60 seconds. The alarm will carry on working in this condition for around another 7 days.  

You should nevertheless change the batteries as soon as possible.

In the event of an alarm, the device can be muted by briefly pressing the 

Test/Mute button

 

(picture 5b)

IEH GmbH

An der Strusbek 40

22926 Ahrensburg/Germany

Internet: www.flammex.de

E-Mail: [email protected]

Summary of Contents for FlammEx profi

Page 1: ...IEH GmbH An der Strusbek 40 22926 Ahrensburg Germany Internet www flammex de E Mail info flammex de MA00118500 09 2012 UW 003929...

Page 2: ...1 2 3 4 c a b 1 2 5 6 7...

Page 3: ...etriebener Ger te einschlie lich zugeh riger L ftungs und Abgassysteme Der FlammEx CO Melder muss nach ca 5 Jahren ausgetauscht werden Befolgen Sie bei der Installation Ihres FlammEx CO Melders genau...

Page 4: ...zur ckzugeben Dies ist unentgeltlich bei der Verkaufsstelle oder bei einer Sammelstelle in der N he m glich 2 Legen Sie die 3 neuen Batterien polrichtig Bild 6 ein und dr cken dabei die roten Stifte...

Page 5: ...this alarm s ability to detect carbon monoxide will not help you e g in the event of gas leaks fire or explosions For such dangers we recommend our FlammEx gas smoke and heat alarms You can find more...

Page 6: ...0 secs off off flashes every battery low see 6 Maintenance 60 secs beeps every 60 secs off off constantly lit alarm is not locked into mounting plate beeps every 2 secs flashes every 2 s flashes every...

Page 7: ...at Pour le montage de votre d tecteur de CO FlammEx veuillez suivre rigoureusement les instructions de cette notice N oubliez pas que ce d tecteur de monoxyde de carbone ne vous prot ge pas de tous le...

Page 8: ...ce stade le d tecteur dispose encore de 7 jours d autonomie mais les piles doivent tre chang es au plus vite Lorsque l alarme retentit vous pouvez l interrompre en appuyant bri vement sur le bouton Te...

Page 9: ...n Volg bij het installeren van uw FlammEx CO melder de instructies in deze gebruiksaanwijzing nauwkeurig op Vergeet niet dat er nog andere gevaren bestaan waarbij de CO detectie van deze melder u niet...

Page 10: ...e volgende 1 5 V alkalinebatterijen formaat AA Mignon Duracell MN 1500 Energizer E91 Nieuwe batterijen gaan onder normale omstandigheden ongeveer 1 jaar mee afhankelijk van het aantal tests Door de me...

Page 11: ...l installazione del rilevatore di CO FlammEx attenersi scrupolosamente alle istruzioni del presente manuale Tenere presente che esistono altri pericoli contro i quali tale rilevatore di CO non efficac...

Page 12: ...est funzionamento Consigliamo di usare le seguenti batterie alcaline da 1 5 V AA Mignon Duracell MN 1500 Energizer E91 In condizioni normali le batterie nuove hanno una durata di ca 1 anno in base al...

Page 13: ...CO detektering inte hj lper mot t ex gasl ckor br nder eller explosioner F r s dana situationer rekommenderar vi v r FlammEx gasvarnare liksom v ra FlammEx r k och v rmedetektorer Mer information hitt...

Page 14: ...samt h g luftfuktighet under l ngre tid blir batteriernas livsl ngd kortare Funktionstest Kontrollera funktionsdugligheten en g ng i veckan genom att snabbt trycka p knappen Test Mute bild 5b Varnaren...

Page 15: ...26 27 FlammEx CO FlammEx 1 CO 2 EN 50292 2001 FlammEx 5 FlammEx FlammEx 3 1 2 3 4 5 6 FlammEx CO 4 CO CO 1 5 2 1 2 1 4 5 3 5a 5b 3 6 3 5c 4 5 6 60 5 5 6 5b D GB F NL I S RUS PL SK CZ H...

Page 16: ...60 60 3 6 1 5 5b 2 3 6 3 4 1 5 Duracell MN 1500 Energizer E91 1 5b 3 5 7 3 x 1 5 AA Mignon EN 50291 85 3 4 C 38 C 10 10 95 125 33 5 50 ppm 60 90 100 ppm 10 40 300 ppm 3 EN 50291 IEH GmbH An der Strusb...

Page 17: ...at Instaluj c czujk CO FlammEx nale y post powa ci le wed ug wskaz wek zawartych w niniejszej instrukcji Nale y pami ta e istniej jeszcze inne zagro enia przy kt rych samo wykrycie czadu przez czujk n...

Page 18: ...a si stosowanie nast puj cych baterii alkalicznych 1 5 V typu AA Mignon Duracell MN 1500 Energizer E91 Nowe baterie w normalnych warunkach starczaj na ok 1 rok w zale no ci od ilo ci wykonywanych pr b...

Page 19: ...plynov Senzor FlammEx CO sa mus po cca 5 rokoch vymeni Pri in tal cii v ho senzora FlammEx CO sledujte presne in trukcie tohto n vodu Berte do vahy e existuj aj in nebezpe enstv pri ktor ch v m nepom...

Page 20: ...A Mignon Duracell MN 1500 Energizer E91 Nov bat rie vydr ia za norm lnych okolnost cca 1 rok v z vislosti od po tu testov Ak je hl si dlh as vystaven vysok m alebo n zkym teplot m alebo vysokej vlhkos...

Page 21: ...instalaci Va eho hl si e CO FlammEx p esn dbejte instrukc tohoto n vodu Uv domte si e existuj je t i dal nebezpe p i kter ch detekce CO tohoto hl si e nepom h nap p i unik n plynu po ru nebo v buchu...

Page 22: ...z test funk nosti Doporu ujeme n sleduj c 1 5 V alkalick baterie velikosti AA Mignon Duracell MN 1500 Energizer E91 Nov baterie vydr za norm ln ch okolnost cca 1 rok v z vislosti na po tu test Je li h...

Page 23: ...A FlammEx CO jelz felszerel se sor n pontosan k vesse az tmutat utas t sait Ne feledje hogy a CO jelz k sz l k sz mtalan vesz lyhelyzetben nem ny jt seg ts get ilyen lehet pl a g zsziv rg s t z vagy r...

Page 24: ...ruza alk lielemeket aj nljuk Duracell MN 1500 Energizer E91 Az j elemek lettartama norm l k r lm nyek k z tt kb 1 v a tesztel sek sz m t l f gg en Ha a jelz t hosszabb ideig alacsony h m rs kletnek va...

Reviews: