Assembly instructions
Translation of the original instructions
June 2018
Page 14 of 47
Module 115/42 (B)
MAN_EN_1057398_Module115-42(B)_R3b.doc
3.4
Wiring
3.4.1
Motors
CAUTION
The electrical connection of the motors is performed according to the motor
data sheet. For customer-specific motors, the data sheet must be requested
from the respective manufacturer and the motor connected accordingly.
3.4.2
Initiators
Inductive proximity switches (PNP normally closed contact, article no.: 025165) are used as
standard limit switches for the running path (see
). These switches are
no safety limit switches pursuant to EN60204-1. Optionally, (also subsequently) an additional
reference point switch (PNP normally open contact article no.: 726744), can be installed in the
linear module 115/42 or 115/42 B. The active button is marked with a coloured circle. Normally
closed contacts are marked with a green, normally open contacts with a red dot. The initiators
and their supply lines are protected in a cable channel integrated in the basic unit, and are
wired to a joint plug.
A plastic strip serves to cover the cable channel. An initiator can be replaced or relocated
easily after removal of this plastic strip from the cable channel.
Figure 9: Scaled sketch of inductive proximity switch