Installation Tips & Check Points
7
p.14
1
Recommended Cable Type and Permissible Length of
Cable
DESCRIPTION
CABLE SPECIFICATION
MAXIMUM DISTANCE
Reader (Power and Data)
Reader <--> ACU
Belden #9512, 22 AWG
4 conductor, shielded
150m
Belden #9514, 22 AWG
8 conductor, shielded
* Should use a wire that is thicker than a wire which can handle maximum current
of the reader.
2
Reader Connection
Long distance between the product and ACU(Access Control Unit) may cause voltage drop.
For example, if you install a reader that consumes 100mA current 100m away from ACU an
d supply power to the reader from the ACU, the voltage drop is 1V. In this case, ACU cannot