THE
ENERGY
FAMILY
(C) IDM ENERGIESYSTEME GMBH
2. General description
Installation instructions TERRA AL Twin
8
1
2
3
4
5
6
7
8
10
11
12
13
1
2
Technical data
Te
chnical d
a
ta
2.3. Performance data
Performace data according to EN14511
AL 17 Twin
Heating capacity at A2/W35
[kW]
17.24
Heating capacity at A7/W35
[kW]
21.67
Heating capacity at A-7/W35
[kW]
14.58
Heating capacity at A2/W45
[kW]
16.63
Heating capacity at A-7/W55
[kW]
13.30
Heating capacity at A2/W35( 1 compressor)
[kW]
10.26
Heating capacity at A7/W35 (1 compressor)
[kW]
12.18
Power input at A2/W35
[kW]
4.23
Power input at A7/W35
[kW]
4.43
Power input at A -7/W35
[kW]
4.31
Power input at A2/W45
[kW]
5.13
Power input at A -7/W55
[kW]
5.93
Power input at A2/W35( 1 compressor)
[kW]
2.21
Power input at A7/W35( 1 compressor)
[kW]
2.23
COP at A2/W35
4.08
COP at A7/W35
4.89
COP at A -7/W35
3.39
COP at A2/W45
3.25
COP at A-7/W55
2.24
COP at A2/W35( 1 compressor)
4.64
COP at A7/W35( 1 compressor)
5.46
Cooling capacity at A35/W18
[kW]
26.31
Cooling capacity at A35/W7
[kW]
17.61
Cooling capacity at A35/W18 (1 compressor)
[kW]
13.98
Power input at A35/W18
[kW]
6.80
Power input at A35/W7
[kW]
6.02
Power input at A35/W18 (1compressor)
[kW]
2.84
EER at A35/W18
3.87
EER at A35/W7
2.93
EER at A35/W18 (1 compressor)
4.92
Dimensions
AL 17 Twin
Dimensions HxWxD
[mm]
1199/1950/925
Weight
[kg]
430