1. General description
Installation instructions TERRA AL Twin
6
1
2
3
4
5
6
7
8
10
11
12
13
1
General description
Genera
l de
sc
ri
pt
ion
The lower the maximum
fl
ow temperature
is, the higher the coef
fi
cient of performance
(COP) of the heat pump will be.
1.12. Description
TERRA AL Twin is a compact air-water-heat pump
with 2 pieces suction gas cooled scroll capsule com-
pressor with largely dimensioned multi-row Al/Cu
fi
nned tube evaporator.
By a special speed-controlled axial fan large volume
fl
ows can be achieved at low speeds.
A copper-welded stainless steel plate heat exchang-
er is used as condenser. The delivery included
fl
ow
switch prevents a freeze up of the condenser in cool-
ing mode, if there is too less
fl
ow volume. The ma-
chine frame consists of a strong metal pro
fi
le. The
cover panels are insulated perfectly. The housing
is thus without a thermal bridge and thus optimum
sound insulated.
The heating controller (Navigator 1.7) developed es-
pecially for this system offers a variety of additional
applications, e.g. Smart Grid, Remote Control or op-
eration via a smart phone. The Navigator 1.7 is lo-
cated in the electrical cabinet and has to be installed
interior.
The heat pump itself is designed in compact con-
struction. The evaporator and the compressors are
mounted side by side. The heat pump is
fi
lled with
refrigerant and is tested in the plant to ensure its per-
fect function.
1.13. Application range
For monovalent heating and cooling of detached,
semi-detached houses and commercial buildings
in appropriate climatic environments. The building
should be furnished with a low-temperature heating
(e.g. under
fl
oor heating, wall heating, low-tempera-
ture radiator heating ...).
TERRA AL Twin heat pumps function with the safety
refrigerant R410A which, if in the event of a proper as-
sembly and installation circulates in a closed circuit,
represents practically no environmental impact.
1.14. Scope of delivery
- Heat pump aggregate with two pieces suction gas
cooled scroll capsule compressors
- Copper-welded stainless steel plate heat exchanger
as condenser
- Finned tube Al/Cu evaporator package
- Speed-controlled axial fan
- two pieces initial current limiter with rotary
fi
eld
monitoring
- Refrigerant collection and dehydration
- Liquid separator
- two pieces electronic expansion valves
- Refrigerant level indicator
- Pressure sensors for high and low-pressure moni-
toring
- Cartridge pressure control switch for high-pressure
monitoring
- Installed switching valve for cooling or defrosting
- Heat and sound-insulated cover panels
- two pieces
fl
exible connection hoses
- Condensate bin and drain tube
- condensate outlet heating
- two pieces compressor-heatings
- sensor package (for one heating circle, Hygienik,
heating buffer, cooling buffer, outdoor)
-
fl
ow switch with T-
fi
tting
- Network socket
1.15. Accessories
see IDM price list