Installation instructions TERRA AL Twin
19
1
2
3
4
min.
2000 mm
min. 200 mm
min. 1000 mm
min. 600 mm
min.
2000 mm
min. 1000 mm
min. 600 mm
condensation outlet
heating side and
electrical connections
heating side and
electrical connections
condensation outlet
Side by side it is possible to cascade up to 5 TERRA AL Twin heat pumps.
min.
2000 mm
min. 600 mm
min.
2000 mm
min. 1000 mm
min. 600 mm
min.
2000 mm
min.
2000 mm
connections
When positioning as shown in example two, there are only 2 heat pumps possible.
The minimum distances must be respected, because of the case of maintainance and to
prevent air-short-circuits.
Placement and Installation
P
lac
ement
a
n
d
In
sta
lla
tion
4.13. Space requirements cascade
Example 1
Example 2