Setting loop back function
If the MSD sends a communication command back to the MSD itself using the loop back function, the MSD
replies “OK” if processed normally while it replies “NG” if parameter or command is incorrect. (This differs
from reply commands to communication commands received externally; not loop back.) Since “OK” and “NG”
are registered to reply commands 31 and 32 by factory default, respectively, do not edit or delete those
commands if you use the loop back function and check reply commands.
[Table 9.29] Default value of reply command
Number
SIZE
PROCESS
DATA
MASK
MEMO
1
0 byte
EXEC
All: 00
All: FF
All: 20 (space)
2
0 byte
EXEC
All: 00
All: FF
All: 20 (space)
:
:
:
:
:
:
30
0 byte
EXEC
All: 00
All: FF
All: 20 (space)
31
2 bytes
EXEC
OK
All: FF
OK
32
2 bytes
STOP
NG
All: FF
NG
■
Setting PJLink