6 Precautions
Before connecting to external devices, follow the precautions below.
6.1 Attaching Rubber feet
First, clean the bottom surface of the IMP as needed, and then peal the release papers from the rubber feet
and place them in each of the four corners.
6.2 Installation
When installing the
IMP
, please observe the following precautions.
・
Do not stack or place one IMP directly on top of another IMP.
・
Do not block vent holes. To provide adequate ventilation, maintain sufficient clearances around
the IMP, 1.2 in. (30 mm) or more.
・
When the IMP needs to be mounted in an enclosed space or an EIA rack without using IDK’s rack
mounting hardware (RM-44S, RM-44D, and RM-SH), ensure that a sufficient ventilation/cooling
system is provided to keep the ambient temperature at 104°F (40°C) or lower. If inadequately vented,
the product’s service life, operation, and reliability may be affected.