![background image](http://html1.mh-extra.com/html/idirect/iq-desktop/iq-desktop_installation-support-and-maintenance-manual_617980029.webp)
Installation, Support, and Maintenance Guide
17
iQ Satellite Router
Configuring the iQ Satellite Router
4.6.2
Installing with DC Power Supply (Option 3)
For an iQ using the DC power supply (Option 3), see
1.
Set the iQ power module switch to the OFF position (0).
2.
Strip approximately 1/4 inch (.6 cm) of insulation from the ends of three appropriately
sized (14-18 AWG) DC input wires. For details see
3.
Loosen the three screws on the terminal block plug (included, P/N Phoenix 1754465).
Insert DC (-), DC (+), and ground wires into the corresponding terminals of the DC
terminal block plug. Fasten securely. Do not over-tighten. For details see
.
4.
Assemble the cable entry housing (included for cable strain relief, P/N 1803947 DigiKey
277-5758-ND) around the three DC wires and terminal block plug, locking pieces securely
with the provided cable tie.
.
5.
Insert the finished terminal block plug, with the cable entry housing, into the terminal
block header in the power supply.
6.
Set the iQ power module switch to the ON position (1).
4.7 Configuring the iQ Satellite Router
When the iQ Satellite Router is physically installed, downloading the software and
configuration of the satellite router need to be completed. Refer to the
Terminal WUI User
Guide
for the release of software installed on the system and for instructions. To download
Satellite Routers
.
4.8 Using the iQ Satellite Router
Change the PC’s Ethernet cable from the Management port ETH 2 to the Data port ETH 1. The
IP address is individually assigned to this port through the remote configuration file. This port
serves the user with access to the Internet.
CAUTION:
If negative voltages are used such as Telecom -48VDC, the negative
most voltage is always connected to –ve terminal (in the Telecom case this would
be -48V) and the positive most voltage is always connected to the +ve terminal (in
the Telecom case this would be 0VR). The Chassis can be referenced to +ve, -ve
or left floating (that is, not connected to ve or –ve) as required because
the power module is fully isolated input to chassis.
NOTE:
The DC source to DC Power Module rating and capacity must be 12-36 V
DC, 9 A.
NOTE:
Per IEC60950-1, the Input voltage is SELV: double/reinforced insulation
must be provided between AC Mains and SELV.