background image

sandpiperpump

.

com

Model HDB1½/HDB40

 • 

14

hdb15dl7sm-rev0217

Pilot Valve Assembly

Step 1: 

With  manifolds  and  outer  chambers 

removed, remove diaphragm assemblies from 

diaphragm rod. 

DO NOT

 use a pipe wrench or similar 

tool to remove assembly from rod. Flaws in the rod 

surface may damage bearings and seal. Soft jaws 

in a vise are recommended to prevent diaphragm 

rod damage.

Step 1.A: 

NOTE: 

Not all inner diaphragm plates 

are threaded. Some models utilize a through hole 

in the inner diaphragm plate. If required to separate 

diaphragm assembly, place assembly in a vise, 

gripping on the exterior cast diameter of the inner 

plate. Turn the outer plate clockwise to separate the 

assembly.

Always  inspect  diaphragms  for  wear  cracks  or 

chemical attack. Inspect inner and outer plates for 

deformities, rust scale and wear. Inspect intermediate 

bearings for elongation and wear. Inspect diaphragm 

rod for wear or marks. 

Clean or repair if appropriate. Replace as required. 

Step 2:

 

Reassembly: There are two different types 

of diaphragm plate assemblies utilized throughout the 

Sandpiper product line: Outer plate with a threaded 

stud, diaphragm, and a threaded inner plate. 

Outer plate with a threaded stud, diaphragm, and 

an inner plate with through hole. Secure threaded 

inner plate in a vise. Ensure that the plates are being 

installed with the outer radius against the diaphragm. 

Step 3:

 Lightly lubricate, with a compatible material, 

the inner faces of both outer and inner diaphragm plates 

when using on non Overlay diaphragms (For EPDM 

water is recommended). No lubrication is required. 

Step 4: 

Push the threaded outer diaphragm 

plate through the center hole of the diaphragm. 

Note: 

Most diaphragms are installed with the 

natural  bulge  out  towards  the  fluid  side.    S05, 

S07,  and  S10  non–metallic  units  are  installed 

with the natural bulge in towards the air side.  

Step 5: 

Thread or place, outer plate stud into 

the inner plate. For threaded inner plates, use a 

torque wrench to tighten the assembly together.  

Torque values are called out on the exploded view. 

Repeat  procedure  for  second  side  assembly. 

Allow  a  minimum  of  15  minutes  to  elapse  after 

torquing, then re-torque the assembly to compensate 

for stress relaxation in the clamped assembly. 

Step 6:

 Thread one assembly onto the diaphragm 

rod with sealing washer (when used) and bumper. 

Step 7: 

Install  diaphragm  rod  assembly 

into pump and secure by installing the outer 

chamber in place and tightening the capscrews. 

Step 8: 

On opposite side of pump, thread the 

remaining assembly onto the diaphragm rod. Using a 

torque wrench, tighten the assembly to the diaphragm 

rod. Align diaphragm through bolt holes, always going 

forward past the recommended torque. Torque values 

are called out on the exploded view. 

NEVER

 reverse 

to align holes, if alignment cannot be achieved 

without damage to diaphragm, loosen complete 

assemblies, rotate diaphragm and reassemble as 

described above. 

Step 9: 

Complete assembly of entire unit.

One  Piece  Diaphragm  Servicing  (Bonded  PTFE 

with integral plate) The One Piece diaphragm has 

a threaded stud installed in the integral plate at the 

factory. The inner diaphragm plate has a through 

hole instead of a threaded hole. Place the inner 

plate over the diaphragm stud and thread the first 

diaphragm / inner plate onto the diaphragm rod only 

until the inner plate contacts the rod. Do not tighten. A 

small amount of grease may be applied between the 

inner plate and the diaphragm to facilitate assembly. 

Insert the diaphragm / rod assembly into the pump 

and install the outer chamber. Turn the pump over 

and thread the second diaphragm / inner plate onto 

the diaphragm rod. Turn the diaphragm until the 

inner plate contacts the rod and hand tighten the 

assembly. Continue tightening until the bolt holes 

align with the inner chamber holes. 

DO NOT LEAVE 

THE ASSEMBLY LOOSE.

Diaphragm  Servicing

IMPORTANT

Read these instructions completely, 

before installation and start-up. 

It is the responsibility of the 

purchaser to retain this manual for 

reference. Failure to comply with 

the recommendations stated in this 

manual will damage the pump, and 

void factory warranty.

UNIVERSAL ALL SP

5: WET END

Summary of Contents for WARREN RUPP SANDPIPER Signature Series

Page 1: ...4 NPT INDICATES DIMENSIONS WITH SUCTION AND DISCHARGE PORTS ROTATED 180 TO A VERTICAL POSITION Warren Rupp Inc A Unit of IDEX Corporation 800 N Main St Mansfield Ohio 44902 USA Telephone 419 524 8388...

Page 2: ...ut or solidify the pump should be flushed after each use to prevent damage In freezing temperatures the pump should be completely drained between uses Before pump operation inspect all fasteners for l...

Page 3: ...Guide Troubleshooting Guide SECTION 3 EXPLODED VIEW 8 Composite Repair Parts Drawing Composite Repair Parts List Down Ported Option Drawing Material Codes SECTION 4 AIR END 12 Air Distribution Valve...

Page 4: ...tainless Steel Wetted Cast Iron Air SS Stainless Steel Wetted Aluminum Air HC Alloy C Wetted Aluminum Air HI Alloy C Wetted Cast Iron Air Pump Series HD Heavy Duty Pump Design B Solid Ball Pump Size O...

Page 5: ...like acetone and MEK ozone chlorinated hydrocarbons and nitro hydrocarbons 190 F 88 C 10 F 23 C Nylon 6 6 High strength and toughness over a wide temperature range Moderate to good resistance to fuel...

Page 6: ...connections 2 23 57 9 96 253 10 63 270 15 50 394 13 87 352 19 5 8 71 221 9 15 232 11 00 279 6 81 173 14 84 377 1 18 30 12 06 306 7 67 195 8 63 219 9 00 229 4X 47 12 1 1 2 NPT 1 1 2 BSP TAPERED DISCHA...

Page 7: ...ions 12 04 306 14 50 368 16 26 413 18 5 5 22 132 17 28 439 10 55 268 11 59 294 17 72 450 6 27 159 9 96 253 23 31 592 15 81 401 10 64 270 12 50 318 10 50 267 8 64 219 8X 44 11 AIR EXHAUST 3 4 NPT 1 1 2...

Page 8: ...check valve and into the outer fluid chamber Suction side stroking also initiates the reciprocating shifting stroking or cycling action of the pump The suction diaphragm s movement is mechanically pu...

Page 9: ...causing the pump to cycle erratically or stop operating Water in the air supply can be reduced by using a point of use air dryer Air Inlet And Priming To start the pump slightly open the air shut off...

Page 10: ...int of use air drier Clogged manifolds Clean manifolds to allow proper air flow Deadhead system pressure meets or exceeds air supply pressure Increase the inlet air pressure to the pump Pump is design...

Page 11: ...nductive Nitrile Seat Gaskets Fabric Manifold Gaskets Nitrile O Rings Nitrile Wear Pads 476 244 363 Wet End Kit FKM Diaphragms FKM Balls Conductive PTFE Seat Gaskets PTFE Manifold Gaskets PTFE Encapsu...

Page 12: ...its 43 24 43 30 24 6 48 50 51 45 47 30 45 Optional Down Ported Conversion Kits 475 022 156 Down Ported Conversion Kit 475 022 010 Down Ported Conversion Kit 475 022 110 Down Ported Conversion Kit 475...

Page 13: ...cription Qty 1 031 019 156 Assembly Main Air Valve Aluminum Center 1 031 019 010 Assembly Main Air Valve Cast Iron Center 1 2 050 005 360W Ball Check 4 050 005 363 Ball Check 4 050 005 364 Ball Check...

Page 14: ...e Rubber 360 Nitrile Rubber Color coded RED 363 FKM Fluorocarbon Color coded YELLOW 364 EPDM Rubber Color coded BLUE 365 Neoprene Rubber Color coded GREEN 366 Food Grade Nitrile 368 Food Grade EPDM 37...

Page 15: ...before installation and start up It is the responsibility of the purchaser to retain this manual for reference Failure to comply with the recommendations stated in this manual will damage the pump and...

Page 16: ...ngs 1 4 E 560 023 360 O Ring Spool 2 4 F 675 037 080 Retaining Ring 1 4 A 4 F 4 D 4 B 4 C 4 E Pilot Valve Servicing With Pilot Valve removed from pump Step 1 Remove snap ring 4 F Step 2 Remove sleeve...

Page 17: ...together Torque values are called out on the exploded view Repeat procedure for second side assembly Allow a minimum of 15 minutes to elapse after torquing then re torque the assembly to compensate f...

Page 18: ...2009 Pumps and Pump Units for Liquids Common Safety Requirements to verify conformance 5 YEAR Limited Product Warranty Warren Rupp Inc Warren Rupp warrants to the original end use purchaser that no p...

Page 19: ...dge apply to the listed equipment AODD Pumps and Surge Suppressors Technical File No 203104000 1410 MER AODD Air Operated Double Diaphragm Pumps EC Type Examination Certificate No Pumps KEMA 09ATEX007...

Reviews: