IDEAL SureTest ST-1THD Instructions Manual Download Page 10

19

Other SureTest Models from IDEAL

SureTest Circuit Analyzers

61-156 

ST

-1THD

61-157 

ST

-1THDC

61-158 

ST

-1THDC

SureTest

®

Selection Guide

Identifies and Locates

Loose Wire Connections

Bad Splices/Receptacles

•     

High Resistance Grounds

•     

False (Bootleg) Grounds

Shared Neutrals

Verifies

Dedicated Circuit Presence

•     

Isolated Ground Presence  (with #61-176 Adapter)

•     

Proper GFCI Operation

Measures

Line Voltage

•     

Ground Impedance (Ohms)

•     

% Voltage Drop under 15 ampere load

•     

% Voltage Drop under 20 ampere load

•     

GFCI Trip Time

•     

Neutral-to-Ground Voltage

•     

Estimated Load on Circuit (Amps)

•     

True RMS Measurements (Voltage)

•     

True RMS Measurements (Current) 

(with #61-181 Adapter)

•    

Line Frequency

•     

Power Consumption (Watts)

•    

Distortion to 31st Harmonic

Additional Features     

220 VAC Operation

For use with #61-181 500AAC Adaptor

•     

Included with #61-181 500AAC Adaptor

Event recording

SureTest Circuit/Harmonics Analyzers

Warranty limited solely to repair or replacement; no warranty of mer-
chantability, fitness for a particular purpose or consequential damages.

IDEAL INDUSTRIES, INC.

Sycamore, IL 60178, U.S.A.
800-435-0705 Customer Assistance
www.idealindustries.com 

ND 2292-1

Made in U.S.A.

61-150 

ST

-1

61-151 

ST

-1P+

61-152 

ST

-1D

61-153 

ST

-1D 

SureTest

®

Selection Guide

Identifies and Locates

Loose Wire Connections

Bad Splices/Receptacles

High Resistance Grounds

False (Bootleg) Grounds

Shared Neutrals

Indicates

Proper Wiring in 3-Wire Receptacles

•     

Min/Max Line Voltage

•     

Pass/Fail Voltage Drop

•     

Pass/Fail Ground Impedance

•     

Pass/Fail Neutral-to-Ground Voltage

Verifies

Dedicated Circuit Presence

Isolated Ground Presence  (with #61-176 Adapter)

Proper GFCI Operation

Measures

Line Voltage

Ground Impedance (Ohms)

% Voltage Drop under 15 ampere load

% Voltage Drop under 20 ampere load

GFCI Trip Time

Neutral-to-Ground Voltage

Estimated Load on Circuit (Amps)

Additional Features     

220 VAC Operation

•     

Summary of Contents for SureTest ST-1THD

Page 1: ...nd Ground Conductors Min Max Avg Peak Neutral to Ground Voltage THD in the Line Voltage and Neutral Current THD per Harmonic up to the 31st Harmonic Line Frequency General Operation The SureTest Model...

Page 2: ...ground conductor Specifications Case Construction GE Cycolac plastic molded Operating Range All measurements except voltage drop FG drop FG conductor resistances 80 300 Volts AC 50 60 Hz Voltage drop...

Page 3: ...HD automatically enters into the out let circuit testing programming menu The LED display cycles between the menu heading and the measurement every four seconds Press and hold the display advance butt...

Page 4: ...edicated circuit Menu Heading Gn Measurement at Menu Heading True RMS Voltage Ground to Neutral Submenu yes Hi Highest Ground to Neutral Voltage Lo Lowest Ground to Neutral Voltage A Average Ground to...

Page 5: ...ecall Memory submenu Pressing the display advance button for three seconds when a blinking rCL is shown on the display will store all of the data into memory overwriting any previous data in memory It...

Page 6: ...a Sto Recording Completed Line Voltage THD Menu Menu Heading LT Measurement at Menu Heading Line Voltage THD Submenu yes HI Highest THD Lo Lowest THD A Average THD LC Crest factor of the line voltage...

Page 7: ...nt at Menu Heading None Submenu yes Blinking rCL Allows access to stored values from memory Sto Stores values into memory Testing with the 61 181 Clamp Adapter These tests can only be accessed by usin...

Page 8: ...on the adapter to a ground such as a metal water or gas pipe prior to GFCI testing 61 176 Isolated Ground Adapter This adapter allows the operator to verify that a receptacle is completely iso lated f...

Page 9: ...e voltage drops the problem is most likely in the circuit between the panel and the first receptacle or at the panel If all branches are in high resistance the problem may be in the cir cuit from the...

Page 10: ...or Event recording SureTest Circuit Harmonics Analyzers Warranty limited solely to repair or replacement no warranty of mer chantability fitness for a particular purpose or consequential damages IDEAL...